Pt/MoS2/Polyaniline Nanocomposite as a Highly Effective Room Temperature Flexible Gas Sensor for Ammonia Detection
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A Pt/MoS 2 /polyaniline (Pt/MoS 2 /PANI) nanocomposite is successfully synthesized by the hydrothermal process combined with the in situ polymerization method, and then Pt particles are decorated on its surface. The Pt/MoS 2 /PANI nanocomposite is deposited on a flexible Au-interdigitated electrode of a polyimide (PI) film. The flexible sensor exhibits a higher response value and fast response/recovery time to NH 3 at room temperature (RT). It results in 2.32-fold and 1.13-fold improvement in the gas-sensing response toward 50 ppm NH 3 compared to those of PANI and MoS 2 /PANI-based gas sensors. The detection limit is 250 ppb. The enhancement sensing mechanisms are attributed to the p–n heterojunction and the Schottky barrier between the three components, which has been confirmed by the current–voltage ( I – V ) curves. A satisfactory selectivity to NH 3 against trimethylamine (TMA) and triethylamine (TEA) is obtained according to density functional theory (DFT), Bader’s analysis, and differential charge density to illustrate the adsorption behavior and charge transfer of gas molecules on the surface of the sensing materials. The sensor retains the excellent sensing response value even under high relative humidity and sensing stability at higher bending angle/numbers to NH 3 gas. Hence, Pt/MoS 2 /PANI can be regarded as a promising sensing material for high-performance NH 3 detection at room temperature applied in flexible wearable electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160
Direct Laser‐Patterned Micro‐Supercapacitors from Paintable MoS2 Films
Cao, L., Yang, S., Gao, W., Liu, Z., Gong, Y., Ma, L., Shi, G., Lei, S., Zhang, Y., Zhang, S., et al. (2013) · Small · doi:10.1002/smll.201203164 · Cited by 513
Quantitative analysis of ammonia on the breath of patients in end-stage renal failure
Davies, S., Spanel, P., & Smith, D. (1997) · Kidney International · doi:10.1038/ki.1997.324 · Cited by 406
Metadata
- Authors
- Tian, X., Cui, X., Xiao, Y., Chen, T., Xiao, X., & Wang, Y.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2023-02-10
- Volume
- 15
- Issue
- 7
- Pages
- 9604-9617
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W4319821972
- Cited by
- 168
- References
- 3
- FWCI
- 12.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pt/MoS2/Polyaniline Nanocomposite as a Highly Effective Room Temperature Flexible Gas Sensor for Ammonia Detection. https://app.cochat.ai/papers/10.1021/acsami.2c20299
- The paper
- Tian, X., Cui, X., Xiao, Y., Chen, T., Xiao, X., & Wang, Y. (2023). Pt/MoS2/Polyaniline Nanocomposite as a Highly Effective Room Temperature Flexible Gas Sensor for Ammonia Detection. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.2c20299
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.