Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 167

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

BODIPY-Based Fluorometric Sensor for the Simultaneous Determination of Cys, Hcy, and GSH in Human Serum

Jia, Ming-Yan, Niu, Li-Ya, Zhang, Yu, Yang, Qing-Zheng, Tung, Chen-Ho, Guan, Ya-Feng, Feng, Liang·2015·ACS Applied Materials & Interfaces

Abstract

Cysteine (Cys), homocysteine (Hcy), and glutathione (GSH) are interconnected and play essential roles for regulating the redox balance of biological processes. However, finding a simple and effective method for the simultaneous determination for these three biothiols in biological systems is always a challenge. In this work, we report a method for the simultaneous quantitative determination of three biothiols in a mixture using a monochlorinated boron dipyrromethene (BODIPY)-based fluorometric sensor. At a specified period of time, after reacting with excess sensor, Hcy and GSH form predominantly sulfur-substituted BODIPY, while Cys generates sulfur-amino-diBODIPY due to a fast substitution-rearrangement-substitution reaction. A significant difference in polarities of these respective major products simplifies their separation by TLC, thus leading to the simultaneous determination of Cys, Hcy, and GSH readily. The sensor was successfully applied for the simultaneous quantitative detection of three biothiols in human serum, and the results were in good agreement with those obtained via high performance liquid chromatography (HPLC).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.5b00122

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 167

Metadata

Authors
Jia, M.-Y., Niu, L.-Y., Zhang, Y., Yang, Q.-Z., Tung, C.-H., Guan, Y.-F., & Feng, L.
Venue
ACS Applied Materials & Interfaces
Published
2015-03-09
Volume
7
Issue
10
Pages
5907-5914
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2322666955
Cited by
167
References
2
FWCI
11.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: BODIPY-Based Fluorometric Sensor for the Simultaneous Determination of Cys, Hcy, and GSH in Human Serum. https://app.cochat.ai/papers/10.1021/acsami.5b00122
The paper
Jia, M.-Y., Niu, L.-Y., Zhang, Y., Yang, Q.-Z., Tung, C.-H., Guan, Y.-F., & Feng, L. (2015). BODIPY-Based Fluorometric Sensor for the Simultaneous Determination of Cys, Hcy, and GSH in Human Serum. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.5b00122

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.