The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Coumarin-Based Turn-On Fluorescence Probe for Specific Detection of Glutathione over Cysteine and Homocysteine
Abstract
We have prepared a turn-on fluorescent probe for biothiols based on bromoketo coumarin (KC-Br). The emission intensity of the coumarin chromophore is modulated by both the heavy atom effect and internal charge transfer (ICT) process. The probe KC-Br is intrinsically nonfluorescent; however, after being reacted with thiols, the bromide moiety is substituted by the -SH group, which elicits a significant fluorescence increase. We surmised the free -NH2 group would further react with carbonyl in the Cys/Hcy-substituted intermediate product yielding to Schiff base compound KC-Cys/KC-Hcy, but not in compound KC-GSH. The ICT effect has a stronger influence in compound KC-GSH than that in compound KC-Cys/KC-Hcy, resulting in compound KC-GSH having a stronger fluorescence. Thus, the probe has a good selectivity for GSH over other various biologically relevant species and even two other similar biothiols (Cys/Hcy) and could image glutathione (GSH) in living cells. We expect the design concept presented in this work would be widely used for the design of fluorescent probes for distinguishing among biothiols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oxidized Redox State of Glutathione in the Endoplasmic Reticulum
Hwang, C., Sinskey, A. J., & Lodish, H. F. (1992) · Science · doi:10.1126/science.1523409 · Cited by 1,968
Saito, C., Zwingmann, C., & Jaeschke, H. (2010) · Hepatology · doi:10.1002/hep.23267 · Cited by 430
Cited by
Coumarin-Based Small-Molecule Fluorescent Chemosensors
Cao, D., Liu, Z., Verwilst, P., Koo, S., Jangjili, P., Kim, J. S., & Lin, W. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00145 · Cited by 1,306
Self-citationFluorescent Probes with Multiple Binding Sites for the Discrimination of Cys, Hcy, and GSH
Yin, C., Xiong, K., Huo, F., Salamanca, J. C., & Strongin, R. M. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201704084 · Cited by 493
Lee, S., Li, J., Zhou, X., Yin, J., & Yoon, J. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2018.03.021 · Cited by 300
Metadata
- Authors
- He, L., Xu, Q., Liu, Y., Wei, H., Tang, Y., & Lin, W.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-06-08
- Volume
- 7
- Issue
- 23
- Pages
- 12809-12813
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2417754043
- Cited by
- 159
- References
- 2
- FWCI
- 10.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coumarin-Based Turn-On Fluorescence Probe for Specific Detection of Glutathione over Cysteine and Homocysteine. https://app.cochat.ai/papers/10.1021/acsami.5b01934
- The paper
- He, L., Xu, Q., Liu, Y., Wei, H., Tang, Y., & Lin, W. (2015). Coumarin-Based Turn-On Fluorescence Probe for Specific Detection of Glutathione over Cysteine and Homocysteine. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.5b01934
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.