Determination of O2Mass Transport at the Pt | PFSA Ionomer Interface under Reduced Relative Humidity
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Oxygen mass transport resistance through the ionomer component in the cathode catalyst layer is considered to contribute overpotential losses in polymer electrolyte membrane fuel cells. Whereas it is known that water uptake, water transport, and proton conductivity are reduced upon reducing relative humidity, the effect on oxygen mass transport remains unknown. We report a two-electrode approach to determine mass transport coefficients for the oxygen reduction reaction in air at the Pt/perfluorosulfonic acid ionomer membrane interface between 90 and 30% RH at 70 °C using a Pt microdisk in a solid state electrochemical cell. Potential-step chronoamperometry was performed at specific mass-transport limiting potentials to allow for the elucidation of the oxygen diffusion coefficient (D(bO2)) and oxygen concentration (c(bO2)). In our efforts, novel approaches in data acquisition, as well as analysis, were examined because of the dynamic nature of the membrane under lowered hydration conditions. Linear regression analysis reveals a decrease in oxygen permeability (D(bO2c(bO2)) by a factor of 1.7 and 3.4 from 90 to 30% RH for Nafion 211 membrane and membranes cast from Nafion DE2020 ionomer solutions, respectively. Additionally, nonlinear curve fitting by way of the Shoup-Szabo equation is employed to analyze the entire current transient during potential step controlled ORR. We also report on the presence of an RH dependence of our previously reported time-dependency measurements for O2 mass transport coefficients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Passalacqua, E., Lufrano, F., Squadrito, G., Patti, A., & Giorgi, L. (2001) · Electrochimica Acta · doi:10.1016/s0013-4686(00)00679-4 · Cited by 440
Optimum Nafion content in PEM fuel cell electrodes
Sasikumar, G., Ihm, J. W., & Ryu, H. (2004) · Electrochimica Acta · doi:10.1016/j.electacta.2004.01.126 · Cited by 187
Bonifácio, R. N., Paschoal, J. O. A., Linardi, M., & Cuenca, R. (2011) · Journal of Power Sources · doi:10.1016/j.jpowsour.2011.01.010 · Cited by 58
Sun, C.-N., More, K. L., Veith, G. M., & Zawodzinski, T. A. (2013) · Journal of The Electrochemical Society · doi:10.1149/2.055309jes · Cited by 28
Cited by
New Insights into Perfluorinated Sulfonic-Acid Ionomers
Kusoglu, A., & Weber, A. Z. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00159 · Cited by 2,432
PEM Fuel cell and electrolysis cell technologies and hydrogen infrastructure development – a review
Wang, Y., Pang, Y., Xu, H., Martinez, A., & Chen, K. S. (2022) · Energy & Environmental Science · doi:10.1039/d2ee00790h · Cited by 828
Nguyen, H., Klose, C., Metzler, L., Vierrath, S., & Breitwieser, M. (2022) · Advanced Energy Materials · doi:10.1002/aenm.202103559 · Cited by 133
Nano-scale control of the ionomer distribution by molecular masking of the Pt surface in PEMFCs
Doo, G., Yuk, S., Lee, J. H., Choi, S., Lee, D.-H., Lee, D. W., Hyun, J., Kwon, S. H., Lee, S. G., & Kim, H.-T. (2020) · Journal of Materials Chemistry A · doi:10.1039/c9ta14002f · Cited by 99
Wang, C., Cheng, X., Yan, X., Shen, S., Ke, C., Wei, G., & Zhang, J. (2019) · Journal of The Electrochemical Society · doi:10.1149/2.0401904jes · Cited by 69
Metadata
- Authors
- Novitski, D., & Holdcroft, S.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-12-03
- Volume
- 7
- Issue
- 49
- Pages
- 27314-27323
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2407521060
- Cited by
- 82
- References
- 4
- FWCI
- 2.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.