The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Pyrene Derivative Emitting Red or near-Infrared Light with Monomer/Excimer Conversion and Its Application to Ratiometric Detection of Hypochlorite
Abstract
Fluorescent sensors are attractive and versatile tools for both chemical sensing and biological imaging. Herein, a novel pyrene derivative fluorophore, Py-Cy, possessing the monomer/excimer conversion feature, was synthesized; and the design rationale for this fluorophore is combination of extending conjugation length and incorporating donor-π-acceptor structure. The positively charged Py-Cy shows quite good water solubility and exhibits absorption in the visible-light range, and its monomer and excimer emit red light and near-infrared light respectively, which is extremely beneficial for biosensing or bioimaging. To explore the potential utilization of this new fluorophore, we choose hypochlorite as a model analyte, which can break the double bond in the molecular structure, thereby generating the water-insoluble pyrenecarboxaldehyde; this process correspondingly leads to fluorescence changes and thus affords the ratiometric fluorescent detection of hypochlorite in real samples and cell imaging. The approach offers new insights for designing other fluorophores which emit red or near-infrared light and for devising technically simple ratiometric fluorescent sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hong, Y., Lam, J. W. Y., & Tang, B. Z. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15113d · Cited by 6,363
A ratiometric fluorescent system for carboxylesterase detection with AIE dots as FRET donors
Wu, Y., Huang, S., Zeng, F., Wang, J., Yu, C., Huang, J., Xie, H., & Wu, S. (2015) · Chemical Communications · doi:10.1039/c5cc04771d · Cited by 105
Self-citation
Cited by
Jiao, X., Li, Y., Niu, J., Xie, X., Wang, X., & Tang, B. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04234 · Cited by 484
Color-tunable single-fluorophore supramolecular system with assembly-encoded emission
Wang, Q., Zhang, Q., Zhang, Q.-W., Li, X., Zhao, C.-X., Xu, T.-Y., Qu, D.-H., & Tian, H. (2020) · Nature Communications · doi:10.1038/s41467-019-13994-6 · Cited by 291
Bioanalytical methods for hypochlorous acid detection: Recent advances and challenges
Zhang, R., Song, B., & Yuan, J. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.11.015 · Cited by 274
Huang, L., Yang, Y., Shao, J., Xiong, G., Wang, H., Nishiura, M., & Hou, Z. (2024) · Journal of the American Chemical Society · doi:10.1021/jacs.3c12342 · Cited by 54
Dong, X., Zhang, G., Shi, J., Wang, Y., Wang, M., Peng, Q., & Zhang, D. (2017) · Chem. Commun. · doi:10.1039/c7cc07092f · Cited by 54
Metadata
- Authors
- Wu, Y., Wang, J., Zeng, F., Huang, S., Huang, J., Xie, H., Yu, C., & Wu, S.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-01-05
- Volume
- 8
- Issue
- 2
- Pages
- 1511-1519
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2216368112
- Cited by
- 212
- References
- 2
- FWCI
- 10.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pyrene Derivative Emitting Red or near-Infrared Light with Monomer/Excimer Conversion and Its Application to Ratiometric Detection of Hypochlorite. https://app.cochat.ai/papers/10.1021/acsami.5b11023
- The paper
- Wu, Y., Wang, J., Zeng, F., Huang, S., Huang, J., Xie, H., Yu, C., & Wu, S. (2016). Pyrene Derivative Emitting Red or near-Infrared Light with Monomer/Excimer Conversion and Its Application to Ratiometric Detection of Hypochlorite. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.5b11023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.