The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Dual-Responsive Carbon Dots for Tumor Extracellular Microenvironment Triggered Targeting and Enhanced Anticancer Drug Delivery
Abstract
In this work, pH/redox dual-responsive carbon dots (CDs-RGD-Pt(IV)-PEG) were fabricated for tumor extracellular microenvironment triggered targeting and enhanced anticancer drug delivery. The system consists of fluorescent carbon dots as imaging-guided drug nanocarriers, cisplatin(IV) as prodrug, and RGD peptide as active targeting ligand, which is covered by monomethoxypolyethylene glycol (mPEG) through tumor extracellular pH (6.5-6.8) responsive benzoic-imine bond. The drug nanocarriers could be tracked by multicolor fluorescence of carbon dots. After the hydrolysis of benzoic-imine bond at the tumor extracellular pH to expose the inner targeting RGD peptide, the drug nanocarriers showed effective uptake by cancer cells through RGD-integrin αvβ3 (ligand-receptor) interaction. Upon the internalization, the loaded cisplatin(IV) prodrug was reduced to cytotoxic cisplatin in reductive cytosol of cancer cells to exhibit therapeutic effects. Confocal imaging, flow cytometry, and cell viability assays using CDs-RGD-Pt(IV)-PEG were performed to reveal the enhanced uptake and better therapeutic efficiency to cancer cells with high integrin αvβ3 expression at tumor extracellular pH than that in physiological condition. The developed CDs-RGD-Pt(IV)-PEG offers a new strategy to provide safe and effective therapeutic agents based on carbon dots for promising cancer therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Walkey, C. D., & Chan, W. C. W. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15233e · Cited by 1,758
Cited by
Carbon quantum dots and their biomedical and therapeutic applications: a review
Molaei, M. J. (2019) · RSC Advances · doi:10.1039/c8ra08088g · Cited by 538
Molaei, M. J. (2019) · Talanta · doi:10.1016/j.talanta.2018.12.042 · Cited by 469
Versatile Types of Organic/Inorganic Nanohybrids: From Strategic Design to Biomedical Applications
Zhao, N., Yan, L., Zhao, X., Chen, X., Li, A., Zheng, D., Zhou, X., Dai, X., & Xu, F.-J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00401 · Cited by 429
The acidic tumor microenvironment: a target for smart cancer nano-theranostics
Feng, L., Dong, Z., Tao, D., Zhang, Y., & Liu, Z. (2018) · National Science Review · doi:10.1093/nsr/nwx062 · Cited by 426
Carbon quantum dots: Preparation, optical properties, and biomedical applications
Yang, H.-L., Bai, L.-F., Geng, Z.-R., Chen, H., Xu, L.-T., Xie, Y.-C., Wang, D.-J., Gu, H.-W., & Wang, X.-M. (2023) · Materials Today Advances · doi:10.1016/j.mtadv.2023.100376 · Cited by 409
Metadata
- Authors
- Feng, T., Ai, X., Ong, H., & Zhao, Y.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-07-12
- Volume
- 8
- Issue
- 29
- Pages
- 18732-18740
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2460935129
- Cited by
- 222
- References
- 1
- FWCI
- 12.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.