The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Metal–Organic Framework Templated Catalysts: Dual Sensitization of PdO–ZnO Composite on Hollow SnO2 Nanotubes for Selective Acetone Sensors
Abstract
Metal–organic framework (MOF)-derived synergistic catalysts were easily functionalized on hollow SnO 2 nanotubes (NTs) via electrospinning and subsequent calcination. Nanoscale Pd NPs (∼2 nm) loaded Zn-based zeolite imidazole framework (Pd@ZIF-8, ∼80 nm) was used as a new catalyst-loading platform for the effective functionalization of a PdO@ZnO complex catalyst onto the thin wall of one-dimensional metal oxide NTs. The well-dispersed nanoscale PdO catalysts (3–4 nm) and multiheterojunctions (PdO/ZnO and ZnO/SnO 2 ) on hollow structures are essential for the development of high-performance gas sensors. As a result, the PdO@ZnO dual catalysts-loaded hollow SnO 2 NTs (PdO@ZnO–SnO 2 NTs) exhibited high acetone response ( R air / R gas = 5.06 at 400 °C @ 1 ppm), superior acetone selectivity against other interfering gases, and fast response (20 s) and recovery (64 s) time under highly humid atmosphere (95% RH). In this work, the advantages of hollow SnO 2 NT structures with high surface area and open porosity were clearly demonstrated by the comparison to SnO 2 nanofibers (NFs). Moreover, the sensor arrays composed of SnO 2 NFs, SnO 2 NTs, PdO@ZnO–SnO 2 NFs, and PdO@ZnO–SnO 2 NTs successfully identified the patterns of the exhaled breath of normal people and simulated diabetics by using a principal component analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metal-organic framework materials as catalysts
Lee, J., Farha, O. K., Roberts, J., Scheidt, K. A., Nguyen, S. T., & Hupp, J. T. (2009) · Chemical Society Reviews · doi:10.1039/b807080f · Cited by 7,969
Cited by
Metal-Organic Frameworks for Chemiresistive Sensors
Koo, W.-T., Jang, J.-S., & Kim, I.-D. (2019) · Chem · doi:10.1016/j.chempr.2019.04.013 · Cited by 680
Self-citationEvolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Functional gas sensing nanomaterials: A panoramic view
Malik, R., Tomer, V. K., Mishra, Y. K., & Lin, L. (2020) · Applied Physics Reviews · doi:10.1063/1.5123479 · Cited by 410
MOF‐Based Chemiresistive Gas Sensors: Toward New Functionalities
Jo, Y., Jo, Y. K., Lee, J., Jang, H. W., Hwang, I., & Yoo, D. J. (2023) · Advanced Materials · doi:10.1002/adma.202206842 · Cited by 410
Porous materials as effective chemiresistive gas sensors
Sharma, A., Eadi, S. B., Noothalapati, H., Otyepka, M., Lee, H.-D., & Jayaramulu, K. (2024) · Chemical Society Reviews · doi:10.1039/d2cs00761d · Cited by 352
Metadata
- Authors
- Koo, W.-T., Jang, J.-S., Choi, S.-J., Cho, H.-J., & Kim, I.-D.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-05-18
- Volume
- 9
- Issue
- 21
- Pages
- 18069-18077
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2612578528
- Cited by
- 197
- References
- 1
- FWCI
- 10.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.