The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
1T-Phase Transition Metal Dichalcogenides (MoS2, MoSe2, WS2, and WSe2) with Fast Heterogeneous Electron Transfer: Application on Second-Generation Enzyme-Based Biosensor
Abstract
Two-dimensional transition metal dichalcogenides (TMDs) have been in the spotlight for their intriguing properties, including a tunable band gap and fast heterogeneous electron-transfer (HET) rate. Understandably, they are especially attractive in the field of electrochemical biosensors. In this article, HET capabilities of various TMDs (MoS 2, MoSe 2, WS 2, and WSe 2 ) within group VI chemically exfoliated via t -BuLi intercalation are studied and these capabilities are used in the second generation electrochemical glucose biosensor. Strikingly, tungsten dichalcogenides (WS 2 and WSe 2 ) exhibit superior HET properties compared to that of their molybdenum counterparts (MoS 2 and MoSe 2 ). When incorporated into second generation glucose biosensors, WS 2 and WSe 2 generated a higher electrochemical responses than that of MoS 2 and MoSe 2, following the same trend as expected. The commendable performance by WX 2 is attributed to the dominance of 1T phase, revealed by characterization data. The developed and optimized 1T WX 2 -based biosensor achieved analytical requirements of selectivity, wide linear ranges, as well as low limits of detection and quantification. The outstanding electrochemical performances of WS 2 and WSe 2 are to be recognized, adding on to the fact that they are not decorated with any metal nanoparticles. This is imperative to showcase the real potential of two-dimensional TMDs in electrochemical biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enhanced catalytic activity in strained chemically exfoliated WS2 nanosheets for hydrogen evolution
Voiry, D., Yamaguchi, H., Li, J., Silva, R., Alves, D. C. B., Fujita, T., Chen, M., Asefa, T., Shenoy, V. B., Eda, G., et al. (2013) · Nature Materials · doi:10.1038/nmat3700 · Cited by 2,641
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Shi, Y., Li, H., & Li, L.-J. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00256c · Cited by 845
Zhang, Y., Zuo, L., Zhang, L., Huang, Y., Lu, H., Fan, W., & Liu, T. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b12772 · Cited by 125
Cited by
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 881
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Two-dimensional materials in biomedical, biosensing and sensing applications
Rohaizad, N., Mayorga-Martinez, C. C., Fojtů, M., Latiff, N. M., & Pumera, M. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00150c · Cited by 506
Self-citationRecent Development of Metallic (1T) Phase of Molybdenum Disulfide for Energy Conversion and Storage
Lei, Z., Zhan, J., Tang, L., Zhang, Y., & Wang, Y. (2018) · Advanced Energy Materials · doi:10.1002/aenm.201703482 · Cited by 485
Synthesis, stabilization and applications of 2-dimensional 1T metallic MoS 2
Shi, S., Sun, Z., & Hu, Y. H. (2018) · Journal of Materials Chemistry A · doi:10.1039/c8ta08152b · Cited by 374
Metadata
- Authors
- Rohaizad, N., Mayorga-Martinez, C. C., Sofer, Z., & Pumera, M.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-11-07
- Volume
- 9
- Issue
- 46
- Pages
- 40697-40706
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2767331333
- Cited by
- 174
- References
- 4
- FWCI
- 6.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.