The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Aptamer-Templated Silver Nanoclusters Embedded in Zirconium Metal–Organic Framework for Bifunctional Electrochemical and SPR Aptasensors toward Carcinoembryonic Antigen
Abstract
This study reported a novel biosensor based on the nanocomposite of zirconium metal–organic framework (Zr-MOF, UiO-66) embedded with silver nanoclusters (Ag NCs) using the carcinoembryonic antigen (CEA)-targeted aptamer as template (AgNCs@Apt@UiO-66). The synthesized AgNCs@Apt@UiO-66 nanocomposite not only possesses good biocompatibility, active electrochemical performance, and strong bioaffinity, but also can be dispersed to form two-dimensional nanocomposite with nanoscale thickness. As such, the use of the AgNCs@CEA-aptamer enables AgNC@Apt@UiO-66 with sensitive and selective detection capacity of trace CEA, further concurrently being exploited as scaffold for surface plasmon resonance spectroscopy (SPR) and electrochemical biosensors. The results showed that the proposed electrochemical AgNC@Apt@UiO-66-based aptasensor exhibits high sensitivity with a low detection limit (LOD) of 8.88 and 4.93 pg·mL –1 deduced from electrochemical impedance spectroscopy and differential pulse voltammetry, respectively, within a broad linear range of the CEA concentration (0.01–10 ng·mL –1 ). Meanwhile, the developed SPR biosensor exhibited a slightly high LOD of 0.3 ng·mL –1 within the CEA concentration of 1.0–250 ng·mL –1 . Both the electrochemical and SPR aptasensors displayed high selectivity, good reproducibility, stability, acceptable regenerability, and applicability in real human serum samples. These results proved that the proposed aptamer-targeted Zr-MOF nanocomposite can be utilized in multiple-functionally biosensing, further promoting the potential application of Zr-MOF-related nanomaterials in clinical diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
He, C., Lu, K., Liu, D., & Lin, W. (2014) · Journal of the American Chemical Society · doi:10.1021/ja4098862 · Cited by 885
Wuttke, S., Lismont, M., Escudero, A., Rungtaweevoranit, B., & Parak, W. J. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.01.025 · Cited by 286
Cited by
Metal-organic framework-based materials as an emerging platform for advanced electrochemical sensing
Liu, C.-S., Li, J., & Pang, H. (2020) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213222 · Cited by 484
Metal-organic frameworks (MOFs) and MOF composites based biosensors
Mohanty, B., Kumari, S., Yadav, P., Kanoo, P., & Chakraborty, A. (2024) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2024.216102 · Cited by 440
Recent advancements in optical biosensors for cancer detection
Kaur, B., Kumar, S., & Kaushik, B. K. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113805 · Cited by 433
Electrochemical biosensors for the detection of lung cancer biomarkers: A review
Khanmohammadi, A., Aghaie, A., Vahedi, E., Qazvini, A., Ghanei, M., Afkhami, A., Hajian, A., & Bagheri, H. (2020) · Talanta · doi:10.1016/j.talanta.2019.120251 · Cited by 358
Aptamer-functionalized metal-organic frameworks (MOFs) for biosensing
Lv, M., Zhou, W., Tavakoli, H., Bautista, C., Xia, J., Wang, Z., & Li, X. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112947 · Cited by 331
Metadata
- Authors
- Guo, C., Su, F., Song, Y., Hu, B., Wang, M., He, L., Peng, D., & Zhang, Z.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-11-16
- Volume
- 9
- Issue
- 47
- Pages
- 41188-41199
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2767779386
- Cited by
- 203
- References
- 2
- FWCI
- 6.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.