The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
High-Performance Wearable Strain Sensor Based on Graphene/Cotton Fabric with High Durability and Low Detection Limit
Abstract
Electronic textiles featuring a controllable strain sensing capability and comfortable wearability have attracted huge interests with the rapid development of wearable strain sensor systems. It is still a great challenge to simultaneously achieve a strain sensor with low cost, biocompatibility, large-area compatibility, and excellent sensing performances. Here, two kinds of cotton fabric-based strain sensors (CFSSs) with different conductive network structures are prepared, i.e., CFSS-90° and CFSS-45° (90° and 45° represent the angles between intertwined direction in cotton yarns and the stretching direction in tension). After multiple dipping processes, graphene nanosheets are deposited onto cotton fabrics, and then, the fabrics are encapsulated by polydimethylsiloxane (PDMS). Morphology analyses reveal that an interpenetrating structure is generated between cotton fabric and PDMS. The strength and elongation at break of CFSS-45° are about 4.5 MPa and 75% strain, which are higher than the counterparts of CFSS-90° (1.75 MPa and 30% strain, respectively). In a uniaxial stretching test, the two strain sensors exhibit excellent linear current-voltage behavior and fast response time (∼90 ms). During the cyclic stretching-releasing test, CFSSs present remarkable reproducibility, durability (10 000 cycles at 30% strain for CFSS-45°), and a sensing capability for detecting very low strain (∼0.4% strain).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Graphene Textile Strain Sensor with Negative Resistance Variation for Human Motion Detection
Yang, Z., Pang, Y., Han, X.-L., Yang, Y., Ling, J., Jian, M., Zhang, Y., Yang, Y., & Ren, T.-L. (2018) · ACS Nano · doi:10.1021/acsnano.8b03391 · Cited by 563
Wang, C., Xia, K., Jian, M., Wang, H., Zhang, M., & Zhang, Y. (2017) · Journal of Materials Chemistry C · doi:10.1039/c7tc01962a · Cited by 169
Lee, T., Lee, W., Kim, S., Kim, J. J., & Kim, B. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201601237 · Cited by 166
Cited by
Liu, H., Chen, X., Zheng, Y., Zhang, D., Zhao, Y., Wang, C., Pan, C., Liu, C., & Shen, C. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008006 · Cited by 625
Self-citationZheng, Y., Yin, R., Zhao, Y., Liu, H., Zhang, D., Shi, X., Zhang, B., Liu, C., & Shen, C. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.127720 · Cited by 469
Self-citationZhou, Y., Sun, Y., Li, Y., Shen, C., Lou, Z., Min, X., & Stewart, R. (2024) · Advanced Intelligent Systems · doi:10.1002/aisy.202400124 · Cited by 17
Self-citation
Metadata
- Authors
- Zheng, Y., Li, Y., Zhou, Y., Dai, K., Zheng, G., Zhang, B., Liu, C., & Shen, C.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-12-11
- Volume
- 12
- Issue
- 1
- Pages
- 1474-1485
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2995650865
- Cited by
- 182
- References
- 4
- FWCI
- 7.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.