CoChat

Fabrication of a Micro-Electromechanical System-Based Acetone Gas Sensor Using CeO2 Nanodot-Decorated WO3 Nanowires

Yuan, Kaiping, Wang, Cheng-Yu, Zhu, Li-Yuan, Cao, Qi, Yang, Jia-He, Li, Xiao-Xi, Huang, Wei, Wang, Yuan-Yuan, Lu, Hong-Liang, Zhang, David Wei · 2020 · ACS Applied Materials & Interfaces
Cited by 186

The DOI matches its Crossref record.

Abstract

Preparation of reliable, stable, and highly responsive gas-sensing devices for the detection of acetone has been considered to be a key issue for the development of accurate disease diagnosis systems via exhaled breath. In this paper, novel CeO 2 nanodot-decorated WO 3 nanowires are successfully synthesized through a sequential hydrothermal and thermolysis process. Such CeO 2 nanodot-decorated WO 3 nanowires exhibited a remarkable enhancement in acetone-sensing performance based on a miniaturized micro-electromechanical system device, which affords high response ( S = 1.30–500 ppb, 1.62–2.5 ppm), low detection limit (500 ppb), and superior selectivity toward acetone. The improved performance of the acetone sensor is likely to be originated from the fast carrier transportation of WO 3 nanowires, the formation of WO 3 –CeO 2 heterojunctions, and the existence of large amounts of oxygen vacancies in CeO 2 . The improved reaction thermodynamics and sensing mechanisms have also been revealed by the specific band alignment and X-ray photoelectron spectroscopy analysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.9b18863

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Yuan, K., Wang, C.-Y., Zhu, L.-Y., Cao, Q., Yang, J.-H., Li, X.-X., Huang, W., Wang, Y.-Y., Lu, H.-L., & Zhang, D. W.
Venue
ACS Applied Materials & Interfaces
Published
2020-02-25
Volume
12
Issue
12
Pages
14095-14104
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W3006956263
Cited by
186
References
0
FWCI
10.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.