Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 184

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Self-Polymerized Dopamine-Decorated Au NPs and Coordinated with Fe-MOF as a Dual Binding Sites and Dual Signal-Amplifying Electrochemical Aptasensor for the Detection of CEA

Li, Jifan, Liu, Lei, Ai, Yongjian, Liu, Yang, Sun, Hongbin, Liang, Qionglin·2020·ACS Applied Materials & Interfaces

Abstract

Fabrication of functional electrochemical biosensor is a hot topic; however, precise and sensitive cancer detection in early clinical diagnosis is still a great challenge. Continuous efforts have been devoted to explore functional materials for this issue. In this work, we developed a dual binding sites and dual signal-amplifying electrochemical aptasensor of self-polymerized dopamine-decorated Au and coordinated with Fe-MOF (Au@PDA@Fe-MOF) for the detection of carcinoembryonic antigen (CEA). Remarkably, Au@PDA@Fe-MOF features high sensitivity, multiple active sites, good biocompatibility, and excellent selectivity, which is attributed to abundant −COOH in porous Fe-MOF and unsaturated Fe 3+ sites on the surface of Fe-MOF as the active binding sites grafting more NH 2 -functionalized CEA-specific aptamer and redox PDA and Fe-MOF accelerating the movement of electrons for dual signal amplifying. Meanwhile, the electrochemical aptasensor shows favorable repeatability with 1.82% relative standard deviation (RSD) under five independent aptasensors and strong stability with only 3.3% degradation after 12 days of storage. In addition, the aptasensor has wide CEA detection range from 1 fg mL –1 to 1 μg mL –1 with a low detection limit of 0.33 fg mL –1 (S/N = 3). Furthermore, the aptasensor is feasible for accurate and quantitative detection of CEA in serum samples with RSD below 2.32%. The satisfying results demonstrate promising applications of the CEA aptasensor in practical sample analysis and lay an important foundation for other biomarker detection in early clinical diagnosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.9b19161

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 184

Metadata

Authors
Li, J., Liu, L., Ai, Y., Liu, Y., Sun, H., & Liang, Q.
Venue
ACS Applied Materials & Interfaces
Published
2020-01-15
Volume
12
Issue
5
Pages
5500-5510
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W3000046378
Cited by
184
References
2
FWCI
8.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Self-Polymerized Dopamine-Decorated Au NPs and Coordinated with Fe-MOF as a Dual Binding Sites and Dual Signal-Amplifying Electrochemical Aptasensor for the Detection of CEA. https://app.cochat.ai/papers/10.1021/acsami.9b19161
The paper
Li, J., Liu, L., Ai, Y., Liu, Y., Sun, H., & Liang, Q. (2020). Self-Polymerized Dopamine-Decorated Au NPs and Coordinated with Fe-MOF as a Dual Binding Sites and Dual Signal-Amplifying Electrochemical Aptasensor for the Detection of CEA. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.9b19161

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.