The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
In Situ Recyclable Surface-Enhanced Raman Scattering-Based Detection of Multicomponent Pesticide Residues on Fruits and Vegetables by the Flower-like MoS2@Ag Hybrid Substrate
Abstract
Pesticides, extensively used in agriculture production, have received enormous attention because of their potential threats to the environment and human health. Hence, in this study, a kind of highly sensitive and stable hybrid surface-enhanced Raman scattering (SERS)-active substrates constructed with flower-like two-dimensional molybdenum sulfide and Ag (MoS 2 @Ag) has been developed, and then the above substrate was sequentially utilized in the recyclable detection of pesticide residues on several kinds of fruits and vegetables. In the first place, the excellent photocatalytic performance of the MoS 2 @Ag hybrid substrate was demonstrated, which was attributed to the inhibition of electron–hole combination after the formation of Schottky barrier between the Ag NPs and MoS 2 matrix. Thereafter, two calibration curves with ultra-low limits of detection (LOD) as 6.4 × 10 –7 and 9.8 × 10 –7 mg/mL were established for the standard solutions of thiram (tetramethylthiuram disulfide, TMTD) and methyl parathion (MP), and then the recyclable assay of their single and mixed residues on eggplant, Chinese cabbage, grape, and strawberry was successfully realized. It is interesting to note that the detection recoveries from 95.5 to 63.1% for TMTD and 92.3 to 62.6% for MP are greatly dependent on the size and surface roughness of these foods. In a word, the MoS 2 @Ag composite matrix shows attractive SERS and photocatalysis performance, and it is expected to have the potential application on food safety monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface-Enhanced Raman Spectroscopy
Haynes, C. L., McFarland, A. D., & Van Duyne, R. P. (2005) · Analytical Chemistry · doi:10.1021/ac053456d · Cited by 1,144
Zheng, X., Xu, J., Yan, K., Wang, H., Wang, Z., & Yang, S. (2014) · Chemistry of Materials · doi:10.1021/cm500347r · Cited by 671
Cited by
Smart plant-wearable biosensor for in-situ pesticide analysis
Zhao, F., He, J., Li, X., Bai, Y., Ying, Y., & Ping, J. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112636 · Cited by 258
Metadata
- Authors
- Chen, Y., Liu, H., Tian, Y., Du, Y., Ma, Y., Zeng, S., Gu, C., Jiang, T., & Zhou, J.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-03-02
- Volume
- 12
- Issue
- 12
- Pages
- 14386-14399
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W3009252141
- Cited by
- 194
- References
- 2
- FWCI
- 23.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.