Graphene-Based Gas Sensors with High Sensitivity and Minimal Sensor-to-Sensor Variation
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Graphene as an atom-thick carbon material is promising for the detection of gaseous molecules owing to extremely high surface-to-volume ratio. However, the majority of graphene-based gas sensors, prepared by chemical vapor deposition (CVD), have suffered from non-uniformity in their responses. Such a high sensor-to-sensor variation in responses has not been systematically studied, limiting application of graphene gas sensors. Here we report processes that lead to a highly sensitive and uniform graphene gas sensor. We examined four types of graphene sensors by varying two conditions: (1) whether or not there is a carbon precursor while cooling down the reactor after graphene synthesis and (2) whether poly(methyl methacrylate) (PMMA), a polymer for transferring the graphene onto another substrate, is removed by annealing at high temperature or by rinsing with acetone. Using 5 ppm dimethyl methylphosphonate (DMMP), a nerve agent simulant, as a model analyte, we found that uniform responses are obtained by cooling down the reactor without carbon precursor and by removing PMMA by annealing. Additional heat treatment of the graphene in air greatly enhances the sensitivity, regardless of the synthesis conditions, by removing residual PMMA and impurities from the graphene surface. The uniform graphene sensors enabled us to find that the edge-to-surface ratio of graphene does not affect sensitivity, whereas noise increases at higher edge-to-surface ratio. Our study presents a design rule for fabricating sensitive and uniform graphene gas sensors, which may facilitate their applications in detecting a broad range of analytes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detection of individual gas molecules adsorbed on graphene
Schedin, F., Geim, A. K., Morozov, S. V., Hill, E. W., Blake, P., Katsnelson, M. I., & Novoselov, K. S. (2007) · Nature Materials · doi:10.1038/nmat1967 · Cited by 8,028
A Review on Graphene-Based Gas/Vapor Sensors with Unique Properties and Potential Applications
Wang, T., Huang, D., Yang, Z., Xu, S., He, G., Li, X., Hu, N., Yin, G., He, D., & Zhang, L. (2016) · Nano-Micro Letters · doi:10.1007/s40820-015-0073-1 · Cited by 600
Cited by
Machine Learning-Based Rapid Detection of Volatile Organic Compounds in a Graphene Electronic Nose
Capman, N. S. S., Zhen, X. V., Nelson, J. T., Chaganti, V. R. S. K., Finc, R. C., Lyden, M. J., Williams, T. L., Freking, M., Sherwood, G. J., Bühlmann, P., et al. (2022) · ACS Nano · doi:10.1021/acsnano.2c10240 · Cited by 115
CO 2 on Graphene: Benchmarking Computational Approaches to Noncovalent Interactions
Ehlert, C., Piras, A., & Gryn’ova, G. (2023) · ACS Omega · doi:10.1021/acsomega.3c03251 · Cited by 15
Metadata
- Authors
- Choi, J. H., Lee, J., Byeon, M., Hong, T. E., Park, H., & Lee, C. Y.
- Venue
- ACS Applied Nano Materials
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-01-30
- Volume
- 3
- Issue
- 3
- Pages
- 2257-2265
- ISSN
- 2574-0970 (ISSN-L)
- OpenAlex
- W3004352145
- Cited by
- 172
- References
- 2
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.