CoChat

Mechanical Regulation of the Cytotoxic Activity of Natural Killer Cells

Open access
Mordechay, Lital, Le Saux, Guillaume, Edri, Avishay, Hadad, Uzi, Porgador, Angel, Schvartzman, Mark · 2021 · ACS Biomaterials Science & Engineering
Cited by 40

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Abstract Mechanosensing has been recently explored for T cells and B cells and is believed to be part of their activation mechanism. Here, we explore the mechanosensing of the third type of lymphocytes – Natural Killer (NK) cells, by showing that they modulate their immune activity in response to changes in the stiffness of a stimulating surface. Interestingly, we found that this immune response is bell-shaped, and peaks for a stiffness of a few hundreds of kPa. This bell-shape behavior was observed only for surfaces functionalized with the activating ligand MHC class I polypeptide-related sequence A (MICA), but not for control surfaces lacking immunoactive functionalities. We found that stiffness does not affect uniformly all cells but increases the size of a little group of extra-active cells, which in turn contribute to the overall activation effect of the entire cell population. We further imaged the clustering of costimulatory adapter protein DAP10 on NK cell membrane and found that it shows the same bell –shape dependence to surface stiffness. Based on these findings, we propose a catch-bond-based model for the mechanoregulation of NK cell cytotoxic activity, through interaction of NKG2D activating receptors with MICA. Our findings reveal what seems to be “the tip of iceberg” of mechanosensation of NK cells, and provides an important insight on the mechanism of their immune signaling. Statement of Significance The mechanical sensing of immune lymphocytes was recently demonstrated for T cells and B cells, but not for the third type of lymphocytes – Natural Killer (NK) cells. Interestingly, previous reports on lymphocyte mechanosensing were controversial, and showed either positive or negative changes in their immune activity with environmental stiffness, depending on the stiffness range. In this paper, we directly demonstrated that NK cells modulate their response with the stiffness of the stimulating surface, and this modulation has a bell-shape trend. We found that there is a strong correlation between the response to stiffness and clustering of adaptor proteins. Upon this correlation, we proposed a mechanosensing model based on the catch-bond nature of activating ligand-receptor complexes in NK cells.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsbiomaterials.0c01121

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 40

Metadata

Authors
Mordechay, L., Le Saux, G., Edri, A., Hadad, U., Porgador, A., & Schvartzman, M.
Venue
ACS Biomaterials Science & Engineering
Published
2020-12-08
Volume
7
Issue
1
Pages
122-132
ISSN
2373-9878 (ISSN-L)
OpenAlex
W3112305242
Cited by
40
References
3
FWCI
1.45
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.