The DOI matches its Crossref record.
Tuning the Bandgap of Photo-Sensitive Polydopamine/Ag3PO4/Graphene Oxide Coating for Rapid, Noninvasive Disinfection of Implants
Open accessAbstract
High Resolution Image Download MS PowerPoint Slide Bacterial infection and associated complications are threats to human health especially when biofilms form on biomedical devices and artificial implants. Herein, a hybrid polydopamine (PDA)/Ag 3 PO 4 /graphene oxide (GO) coating is designed and constructed to achieve rapid bacteria killing and eliminate biofilms in situ. By varying the amount of GO in the hybrid coating, the bandgap can be tuned from 2.52 to 2.0 eV so that irradiation with 660 nm visible light produces bacteria-killing effects synergistically in concert with reactive oxygen species (ROS). GO regulates the release rate of Ag + to minimize the cytotoxicity while maintaining high antimicrobial activity, and a smaller particle size enhances the yield of ROS. After irradiation with 660 nm visible light for 15 min, the antimicrobial rates of the PDA/Ag 3 PO 4 /GO hybrid coating against Escherichia coli and Staphylococcus aureus are 99.53% and 99.66%, respectively. In addition, this hybrid coating can maintain a repeatable and sustained antibacterial efficacy. The released Ag + and photocatalytic Ag 3 PO 4 produce synergistic antimicrobial effects in which the ROS increases the permeability of the bacterial membranes to increase the probability of Ag + to enter the cells to kill them together with ROS synergistically.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wang, C., Wang, M., Xu, T., Zhang, X., Lin, C., Gao, W., Xu, H., Lei, B., & Mao, C. (2019) · Theranostics · doi:10.7150/thno.29766 · Cited by 908
Self-citationEmerging photothermal-derived multimodal synergistic therapy in combating bacterial infections
Huo, J., Jia, Q., Huang, H., Zhang, J., Li, P., Dong, X., & Huang, W. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00074h · Cited by 847
Zhou, L., Zheng, H., Liu, Z., Wang, S., Liu, Z., Chen, F., Zhang, H., Kong, J., Zhou, F., & Zhang, Q. (2021) · ACS Nano · doi:10.1021/acsnano.0c06287 · Cited by 382
Photocatalytic Antimicrobials: Principles, Design Strategies, and Applications
Ran, B., Ran, L., Wang, Z., Liao, J., Li, D., Chen, K., Cai, W., Hou, J., & Peng, X. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00326 · Cited by 357
Buchman, J. T., Hudson-Smith, N. V., Landy, K. M., & Haynes, C. L. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00053 · Cited by 304
Metadata
- Authors
- Xie, X., Mao, C., Liu, X., Tan, L., Cui, Z., Yang, X., Zhu, S., Li, Z., Yuan, X., Zheng, Y., Yeung, K. W. K., Chu, P. K., & Wu, S.
- Venue
- ACS Central Science
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-06-05
- Volume
- 4
- Issue
- 6
- Pages
- 724-738
- ISSN
- 2374-7943 (ISSN-L)
- 2374-7951
- OpenAlex
- W2806260871
- Cited by
- 271
- References
- 0
- FWCI
- 24.52
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tuning the Bandgap of Photo-Sensitive Polydopamine/Ag3PO4/Graphene Oxide Coating for Rapid, Noninvasive Disinfection of Implants. https://app.cochat.ai/papers/10.1021/acscentsci.8b00177
- The paper
- Xie, X., Mao, C., Liu, X., Tan, L., Cui, Z., Yang, X., Zhu, S., Li, Z., Yuan, X., Zheng, Y., Yeung, K. W. K., Chu, P. K., & Wu, S. (2018). Tuning the Bandgap of Photo-Sensitive Polydopamine/Ag3PO4/Graphene Oxide Coating for Rapid, Noninvasive Disinfection of Implants. ACS Central Science. https://doi.org/10.1021/acscentsci.8b00177
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.