The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Two-Dimensional-Material-Based Field-Effect Transistor Biosensor for Detecting COVID-19 Virus (SARS-CoV-2)
Abstract
The emergence of rapidly expanding infectious diseases such as coronavirus (COVID-19) demands effective biosensors that can promptly detect and recognize the pathogens. Field-effect transistors based on semiconducting two-dimensional (2D) materials (2D-FETs) have been identified as potential candidates for rapid and label-free sensing applications. This is because any perturbation of such atomically thin 2D channels can significantly impact their electronic transport properties. Here, we report the use of FET based on semiconducting transition metal dichalcogenide (TMDC) WSe 2 as a promising biosensor for the rapid and sensitive detection of SARS-CoV-2 in vitro . The sensor is created by functionalizing the WSe 2 monolayers with a monoclonal antibody against the SARS-CoV-2 spike protein and exhibits a detection limit of down to 25 fg/μL in 0.01X phosphate-buffered saline (PBS). Comprehensive theoretical and experimental studies, including density functional theory, atomic force microscopy, Raman and photoluminescence spectroscopies, and electronic transport properties, were performed to characterize and explain the device performance. The results demonstrate that TMDC-based 2D-FETs can potentially serve as sensitive and selective biosensors for the rapid detection of infectious diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electronics and optoelectronics of two-dimensional transition metal dichalcogenides
Wang, Q. H., Kalantar-Zadeh, K., Kis, A., Coleman, J. N., & Strano, M. S. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.193 · Cited by 16,374
Advanced capabilities for materials modelling with Q uantum ESPRESSO
Giannozzi, P., Andreussi, O., Brumme, T., Bunau, O., Buongiorno Nardelli, M., Calandra, M., Car, R., Cavazzoni, C., Ceresoli, D., Cococcioni, M., et al. (2017) · Journal of Physics: Condensed Matter · doi:10.1088/1361-648x/aa8f79 · Cited by 8,361
Ultrasensitive reversible oxygen sensing by using liquid-exfoliated MoS 2 nanoparticles
Kim, Y. H., Kim, K. Y., Choi, Y. R., Shim, Y.-S., Jeon, J.-M., Lee, J.-H., Kim, S. Y., Han, S., & Jang, H. W. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta01277a · Cited by 90
Cited by
Two-Dimensional Field-Effect Transistor Sensors: The Road toward Commercialization
Dai, C., Liu, Y., & Wei, D. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00924 · Cited by 303
Metadata
- Authors
- Fathi-Hafshejani, P., Azam, N., Wang, L., Kuroda, M. A., Hamilton, M. C., Hasim, S., & Mahjouri-Samani, M.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-06-28
- Volume
- 15
- Issue
- 7
- Pages
- 11461-11469
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W3177283875
- Cited by
- 241
- References
- 3
- FWCI
- 13.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Two-Dimensional-Material-Based Field-Effect Transistor Biosensor for Detecting COVID-19 Virus (SARS-CoV-2). https://app.cochat.ai/papers/10.1021/acsnano.1c01188
- The paper
- Fathi-Hafshejani, P., Azam, N., Wang, L., Kuroda, M. A., Hamilton, M. C., Hasim, S., & Mahjouri-Samani, M. (2021). Two-Dimensional-Material-Based Field-Effect Transistor Biosensor for Detecting COVID-19 Virus (SARS-CoV-2). ACS Nano. https://doi.org/10.1021/acsnano.1c01188
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.