Polymer Nanocomposite Dielectrics: Understanding the Matrix/Particle Interface
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Polymer nanocomposite dielectrics possess exceptional electric properties that are absent in the pristine dielectric polymers. The matrix/particle interface in polymer nanocomposite dielectrics is suggested to play decisive roles on the bulk material performance. Herein, we present a critical overview of recent research advances and important insights in understanding the matrix/particle interfacial characteristics in polymer nanocomposite dielectrics. The primary experimental strategies and state-of-the-art characterization techniques for resolving the local property-structure correlation of the matrix/particle interface are dissected in depth, with a focus on the characterization capabilities of each strategy or technique that other approaches cannot compete with. Limitations to each of the experimental strategy are evaluated as well. In the last section of this Review, we summarize and compare the three experimental strategies from multiple aspects and point out their advantages and disadvantages, critical issues, and possible experimental schemes to be established. Finally, the authors' personal viewpoints regarding the challenges of the existing experimental strategies are presented, and potential directions for the interface study are proposed for future research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Infrared and Raman chemical imaging and spectroscopy at the nanoscale
Kurouski, D., Dazzi, A., Zenobi, R., & Centrone, A. (2020) · Chemical Society Reviews · doi:10.1039/c8cs00916c · Cited by 324
Dynamics of entangled chains in polymer nanocomposites
Schneider, G. J., Nusser, K., Willner, L., Falus, P., & Richter, D. (2011) · Macromolecules · doi:10.1021/ma200899y · Cited by 151
(2007) · doi:10.1007/978-3-540-68411-4 · Cited by 36
Cited by
Polymer nanocomposite dielectrics for capacitive energy storage
Yang, M., Guo, M., Xu, E., Ren, W., Wang, D., Li, S., Zhang, S., Nan, C.-W., & Shen, Y. (2024) · Nature Nanotechnology · doi:10.1038/s41565-023-01541-w · Cited by 423
Metadata
- Authors
- Wang, S., Luo, Z., Liang, J., Hu, J., Jiang, N., He, J., & Li, Q.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2022-09-15
- Volume
- 16
- Issue
- 9
- Pages
- 13612-13656
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W4295908241
- Cited by
- 232
- References
- 4
- FWCI
- 11.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polymer Nanocomposite Dielectrics: Understanding the Matrix/Particle Interface. https://app.cochat.ai/papers/10.1021/acsnano.2c07404
- The paper
- Wang, S., Luo, Z., Liang, J., Hu, J., Jiang, N., He, J., & Li, Q. (2022). Polymer Nanocomposite Dielectrics: Understanding the Matrix/Particle Interface. ACS Nano. https://doi.org/10.1021/acsnano.2c07404
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.