CoChat

An Antisweat Interference and Highly Sensitive Temperature Sensor Based on Poly(3,4-ethylenedioxythiophene)–Poly(styrenesulfonate) Fiber Coated with Polyurethane/Graphene for Real-Time Monitoring of Body Temperature

Open access
Fan, Wei, Liu, Tong, Wu, Fan, Wang, Shujuan, Ge, Shengbo, Li, Yunhong, Liu, Jinlin, Ye, Haoran, Lei, Ruixin, Wang, Chan, Che, Qiuling, Li, Yi · 2023 · ACS Nano
Cited by 223

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

High Resolution Image Download MS PowerPoint Slide Body temperature is an important indicator of human health. The traditional mercury and medical electronic thermometers have a slow response (≥1 min) and can not be worn for long to achieve continuous temperature monitoring due to their rigidity. In this work, we prepared a skin-core structure polyurethane (PU)/graphene encapsulated poly(3,4-ethylenedioxythiophene)–poly(styrenesulfonate) (PEDOT:PSS) temperature-sensitive fiber in one step by combining wet spinning technology with impregnation technology. The composite fiber has high sensitivity (−1.72%/°C), super-resolution (0.1 °C), fast time response (17 s), antisweat interference, and high linearity ( R 2 = 0.98) in the temperature sensing range of 30–50 °C. The fiber is strong enough to be braided into the temperature-sensitive fabric with commercial cotton yarns. The fabric with good comfort and durability can be arranged in the armpit position of the cloth to realize real-time body temperature monitoring without interruption during daily activities. Through Bluetooth wireless transmission, body temperature can be monitored in real-time and displayed on mobile phones to the parents or guardians. Overall, the fiber-based temperature sensor will significantly improve the practical applications of wearable temperature sensors in intelligent medical treatment due to its sensing stability, comfort, and durability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsnano.3c04246

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Metadata

Authors
Fan, W., Liu, T., Wu, F., Wang, S., Ge, S., Li, Y., Liu, J., Ye, H., Lei, R., Wang, C., Che, Q., & Li, Y.
Venue
ACS Nano
Published
2023-10-24
Volume
17
Issue
21
Pages
21073-21082
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W4387899784
Cited by
223
References
2
FWCI
16.36
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Antisweat Interference and Highly Sensitive Temperature Sensor Based on Poly(3,4-ethylenedioxythiophene)–Poly(styrenesulfonate) Fiber Coated with Polyurethane/Graphene for Real-Time Monitoring of Body Temperature. https://app.cochat.ai/papers/10.1021/acsnano.3c04246
The paper
Fan, W., Liu, T., Wu, F., Wang, S., Ge, S., Li, Y., Liu, J., Ye, H., Lei, R., Wang, C., Che, Q., & Li, Y. (2023). An Antisweat Interference and Highly Sensitive Temperature Sensor Based on Poly(3,4-ethylenedioxythiophene)–Poly(styrenesulfonate) Fiber Coated with Polyurethane/Graphene for Real-Time Monitoring of Body Temperature. ACS Nano. https://doi.org/10.1021/acsnano.3c04246

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.