The DOI matches its Crossref record; the references it cites are not checked yet.
Ultrathin Self-Powered Heavy-Metal-Free Cu–In–Se Quantum Dot Photodetectors for Wearable Health Monitoring
Abstract
Mechanically deformable photodetectors (PDs) are key device components for wearable health monitoring systems based on photoplethysmography (PPG). Achieving high detectivity, fast response time, and an ultrathin form factor in the PD is highly needed for next-generation wearable PPG systems. Self-powered operation without a bulky power-supply unit is also beneficial for point-of-care application. Here, we propose ultrathin self-powered PDs using heavy-metal-free Cu–In–Se quantum dots (QDs), which enable high-performance wearable PPG systems. Although the light-absorbing QD layer is extremely thin (∼40 nm), the developed PD exhibits excellent performance (specific detectivity: 2.10 × 10 12 Jones, linear dynamic range: 102 dB, and spectral range: 250–1050 nm at zero bias), which is comparable to that of conventional rigid QD-PDs employing thick Pb-chalcogenide QD layers. This is attributed to material and device strategies─materials that include Cu–In–Se QDs, a MoS 2 -nanosheet-blended poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) hole transport layer, a ZnO nanoparticle electron transport layer, Ag and ITO electrodes, and an ultrathin form factor (∼120 nm except the electrodes) that enable excellent mechanical deformability. These allow the successful application of QD-PDs to a wearable system for real-time PPG monitoring, expanding their potential in the field of mobile bioelectronics.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
The citation lists haven’t been fetched yet
References 77 · Cited by 70
Metadata
- Authors
- Li, S., Jang, J. H., Chung, W., Seung, H., Park, S. I., Ma, H., Pyo, W. J., Choi, C., Chung, D. S., Kim, D.-H., Choi, M. K., & Yang, J.
- Affiliations
- Daegu Gyeongbuk Institute of Science and Technology (KR)
- Ulsan National Institute of Science and Technology (KR)
- Seoul National University (KR)
- Pohang University of Science and Technology (KR)
- Korea Institute of Science and Technology (KR)
- Institute for Basic Science (KR)
- Corresponding author
- Kim, Dae-Hyeong
- Choi, Moon Kee
- Yang, Jiwoong
- ORCID
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2023-10-03
- Volume
- 17
- Issue
- 20
- Pages
- 20013-20023
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W4387296536
- Cited by
- 70
- References
- 77
- Citations by year
- 2026: 18 · 2025: 27 · 2024: 22 · 2023: 3
- FWCI
- 5.15
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- ACS Nano (publishedVersion)
- PubMed (publishedVersion)
- Seoul National University Open Repository (Seoul National University) (submittedVersion)
- Scholarworks@UNIST (Ulsan National Institute of Science and Technology) (submittedVersion)
- Funders
- Ministry of Science and ICT, South Korea (2021R1C1C1007844, 2021R1C1C1007997, 23-SENS2-6)
- Institute for Basic Science (IBS-R006-A1, IBS-R006-D1)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Quantum Dots Synthesis And Properties
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- self-powered photodetectors, wearable health monitoring, photoplethysmography, heavy-metal-free quantum dots, PEDOT:PSS hole transport layer, ZnO electron transport layer, point-of-care monitoring
- MeSH terms
- Wearable Electronic Devices, Electrodes, Electric Power Supplies, Metals, Heavy, Quantum Dots, Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review