Cited by 70Quantum Dots Synthesis And PropertiesNon-Invasive Vital Sign MonitoringAdvanced Sensor and Energy Harvesting Materials

The DOI matches its Crossref record; the references it cites are not checked yet.

Ultrathin Self-Powered Heavy-Metal-Free Cu–In–Se Quantum Dot Photodetectors for Wearable Health Monitoring

Abstract

Mechanically deformable photodetectors (PDs) are key device components for wearable health monitoring systems based on photoplethysmography (PPG). Achieving high detectivity, fast response time, and an ultrathin form factor in the PD is highly needed for next-generation wearable PPG systems. Self-powered operation without a bulky power-supply unit is also beneficial for point-of-care application. Here, we propose ultrathin self-powered PDs using heavy-metal-free Cu–In–Se quantum dots (QDs), which enable high-performance wearable PPG systems. Although the light-absorbing QD layer is extremely thin (∼40 nm), the developed PD exhibits excellent performance (specific detectivity: 2.10 × 10 12 Jones, linear dynamic range: 102 dB, and spectral range: 250–1050 nm at zero bias), which is comparable to that of conventional rigid QD-PDs employing thick Pb-chalcogenide QD layers. This is attributed to material and device strategies─materials that include Cu–In–Se QDs, a MoS 2 -nanosheet-blended poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) hole transport layer, a ZnO nanoparticle electron transport layer, Ag and ITO electrodes, and an ultrathin form factor (∼120 nm except the electrodes) that enable excellent mechanical deformability. These allow the successful application of QD-PDs to a wearable system for real-time PPG monitoring, expanding their potential in the field of mobile bioelectronics.

Overview

Integrity signals

Registry

Crossref · 10.1021/acsnano.3c05178

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

The citation lists haven’t been fetched yet

References 77 · Cited by 70

Metadata

Authors
Li, S., Jang, J. H., Chung, W., Seung, H., Park, S. I., Ma, H., Pyo, W. J., Choi, C., Chung, D. S., Kim, D.-H., Choi, M. K., & Yang, J.
Affiliations
  • Daegu Gyeongbuk Institute of Science and Technology (KR)
  • Ulsan National Institute of Science and Technology (KR)
  • Seoul National University (KR)
  • Pohang University of Science and Technology (KR)
  • Korea Institute of Science and Technology (KR)
  • Institute for Basic Science (KR)
Corresponding author
  • Kim, Dae-Hyeong
  • Choi, Moon Kee
  • Yang, Jiwoong
Venue
ACS Nano
Published
2023-10-03
Volume
17
Issue
20
Pages
20013-20023
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W4387296536
Cited by
70
References
77
Citations by year
2026: 18 · 2025: 27 · 2024: 22 · 2023: 3
FWCI
5.15
Type
journal article
Language
en
Open access
closed
Locations
  • ACS Nano (publishedVersion)
  • PubMed (publishedVersion)
  • Seoul National University Open Repository (Seoul National University) (submittedVersion)
  • Scholarworks@UNIST (Ulsan National Institute of Science and Technology) (submittedVersion)
Funders
  • Ministry of Science and ICT, South Korea (2021R1C1C1007844, 2021R1C1C1007997, 23-SENS2-6)
  • Institute for Basic Science (IBS-R006-A1, IBS-R006-D1)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Quantum Dots Synthesis And Properties
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
self-powered photodetectors, wearable health monitoring, photoplethysmography, heavy-metal-free quantum dots, PEDOT:PSS hole transport layer, ZnO electron transport layer, point-of-care monitoring
MeSH terms
Wearable Electronic Devices, Electrodes, Electric Power Supplies, Metals, Heavy, Quantum Dots, Nanoparticles

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review