The DOI matches its Crossref record.
Stable and Selective Humidity Sensing Using Stacked Black Phosphorus Flakes
Abstract
Black phosphorus (BP) atomic layers are known to undergo chemical degradation in humid air. Yet in more robust configurations such as films, composites, and embedded structures, BP can potentially be utilized in a large number of practical applications. In this study, we explored the sensing characteristics of BP films and observed an ultrasensitive and selective response toward humid air with a trace-level detection capability and a very minor drift over time. Our experiments show that the drain current of the BP sensor increases by ∼4 orders of magnitude as the relative humidity (RH) varies from 10% to 85%, which ranks it among the highest ever reported values for humidity detection. The mechanistic studies indicate that the operation principle of the BP film sensors is based on the modulation in the leakage ionic current caused by autoionization of water molecules and ionic solvation of the phosphorus oxoacids produced on moist BP surfaces. Our stability tests reveal that the response of the BP film sensors remains nearly unchanged after prolonged exposures (up to 3 months) to ambient conditions. This study opens up the route for utilizing BP stacked films in many potential applications such as energy generation/storage systems, electrocatalysis, and chemical/biosensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advanced Carbon for Flexible and Wearable Electronics
Wang, C., Xia, K., Wang, H., Liang, X., Yin, Z., & Zhang, Y. (2019) · Advanced Materials · doi:10.1002/adma.201801072 · Cited by 1,300
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Interaction of Black Phosphorus with Oxygen and Water
Huang, Y., Qiao, J., He, K., Bliznakov, S., Sutter, E., Chen, X., Luo, D., Meng, F., Su, D., Decker, J., et al. (2016) · Chemistry of Materials · doi:10.1021/acs.chemmater.6b03592 · Cited by 532
Black Phosphorus Rediscovered: From Bulk Material to Monolayers
Gusmão, R., Sofer, Z., & Pumera, M. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201610512 · Cited by 521
Superior Chemical Sensing Performance of Black Phosphorus: Comparison with MoS2 and Graphene
Cho, S., Lee, Y., Koh, H., Jung, H., Kim, J., Yoo, H., Kim, J., & Jung, H. (2016) · Advanced Materials · doi:10.1002/adma.201601167 · Cited by 431
Metadata
- Authors
- Yasaei, P., Behranginia, A., Foroozan, T., Asadi, M., Kim, K., Khalili-Araghi, F., & Salehi-Khojin, A.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-09-30
- Volume
- 9
- Issue
- 10
- Pages
- 9898-9905
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2239020482
- Cited by
- 239
- References
- 0
- FWCI
- 14.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stable and Selective Humidity Sensing Using Stacked Black Phosphorus Flakes. https://app.cochat.ai/papers/10.1021/acsnano.5b03325
- The paper
- Yasaei, P., Behranginia, A., Foroozan, T., Asadi, M., Kim, K., Khalili-Araghi, F., & Salehi-Khojin, A. (2015). Stable and Selective Humidity Sensing Using Stacked Black Phosphorus Flakes. ACS Nano. https://doi.org/10.1021/acsnano.5b03325
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.