Hybridized Electromagnetic–Triboelectric Nanogenerator for a Self-Powered Electronic Watch

Quan, Ting, Wang, Xue, Wang, Zhong Lin, Yang, Ya·2015·ACS Nano

Abstract

We report a hybridized nanogenerator including a triboelectric nanogenerator (TENG) and six electromagnetic generators (EMGs) that can effectively scavenge biomechanical energy for sustainably powering an electronic watch. Triggered by the natural motions of the wearer's wrist, a magnetic ball at the center in an acrylic box with coils on each side will collide with the walls, resulting in outputs from both the EMGs and the TENG. By using the hybridized nanogenerator to harvest the biomechanical energy, the electronic watch can be continuously powered under different motion types of the wearer's wrist, where the best approach is to charge a 100 μF capacitor in 39 s to maintain the continuous operation of the watch for 456 s. To increase the working time of the watch further, a homemade Li-ion battery has been utilized as the energy storage unit for realizing the continuous working of the watch for about 218 min by using the hybridized nanogenerator to charge the battery within 32 min. This work will provide the opportunities for developing a nanogenerator-based built-in power source for self-powered wearable electronics such as an electronic watch.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsnano.5b05598

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 19

  1. 10.1038/nbt.2952 · DOI · Paper page
  2. 10.1021/nn507455f · DOI · Paper page
  3. 10.1021/nn306044d · DOI · Paper page
  4. 10.1126/science.1111063 · DOI · Paper page
  5. 10.1126/science.1149860 · DOI · Paper page
  6. 10.1016/j.nanoen.2015.01.051 · DOI · Paper page
  7. 10.1016/j.nanoen.2014.10.010 · DOI
  8. 10.1109/40.928763 · DOI · Paper page
  9. 10.1021/nn406481k · DOI · Paper page
  10. 10.1002/adma.201001169 · DOI · Paper page
  11. 10.1016/j.nanoen.2012.01.004 · DOI · Paper page
  12. 10.1039/c3ee42311e · DOI · Paper page
  13. 10.1039/C3TA14421F · DOI
  14. 10.1016/j.nanoen.2013.03.001 · DOI · Paper page
  15. 10.1002/adma.201400207 · DOI · Paper page
  16. 10.1021/nn502684f · DOI
  17. 10.1016/j.nanoen.2015.03.012 · DOI · Paper page
  18. 10.1016/j.nanoen.2014.10.035 · DOI
  19. 10.1021/la00040a030 · DOI

Cited by

See all 215

Metadata

Authors
Quan, T., Wang, X., Wang, Z. L., & Yang, Y.
Venue
ACS Nano
Published
2015-11-13
Volume
9
Issue
12
Pages
12301-12310
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W2412935015
Cited by
215
References
1
FWCI
8.49
Type
journal article
Language
en
Open access
closed
Funders
  • Chinese Academy of Sciences (CAS-ITRI201501)
  • Natural Science Foundation of Beijing Municipality (2154059)
  • Thousands Talents Program for Pioneer Researcher and his Innovation Team
  • National Natural Science Foundation of China (51472055, 61404034)
  • Industrial Technology Research Institute (CAS-ITRI201501)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.