The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Knitted Carbon-Nanotube-Sheath/Spandex-Core Elastomeric Yarns for Artificial Muscles and Strain Sensing
Abstract
Highly stretchable, actuatable, electrically conductive knitted textiles based on Spandex (SPX)/CNT (carbon nanotube) composite yarns were prepared by an integrated knitting procedure. SPX filaments were continuously wrapped with CNT aerogel sheets and supplied directly to an interlocking circular knitting machine to form three-dimensional electrically conductive and stretchable textiles. By adjusting the SPX/CNT feed ratio, the fabric electrical conductivities could be tailored in the range of 870 to 7092 S/m. The electrical conductivity depended on tensile strain, with a linear and largely hysteresis-free resistance change occurring on loading and unloading between 0% and 80% strain. Electrothermal heating of the stretched fabric caused large tensile contractions of up to 33% and generated a gravimetric mechanical work capacity during contraction of up to 0.64 kJ/kg and a maximum specific power output of 1.28 kW/kg, which far exceeds that of mammalian skeletal muscle. The knitted textile provides the combination of strain sensing and the ability to control dimensions required for smart clothing that simultaneously monitors the wearer's movements and adjusts the garment fit or exerts forces or pressures on the wearer, according to needs. The developed processing method is scalable for the fabrication of industrial quantities of strain sensing and actuating smart textiles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres
Pang, C., Lee, G.-Y., Kim, T.-I., Kim, S. M., Kim, H. N., Ahn, S.-H., & Suh, K.-Y. (2012) · Nature Materials · doi:10.1038/nmat3380 · Cited by 1,695
Cited by
Smart Textile‐Integrated Microelectronic Systems for Wearable Applications
Shi, J., Liu, S., Zhang, L., Yang, B., Shu, L., Yang, Y., Ren, M., Wang, Y., Chen, J., Chen, W., et al. (2020) · Advanced Materials · doi:10.1002/adma.201901958 · Cited by 822
Significance of Nanomaterials in Wearables: A Review on Wearable Actuators and Sensors
Jayathilaka, W. A. D. M., Qi, K., Qin, Y., Chinnappan, A., Serrano‐García, W., Baskar, C., Wang, H., He, J., Cui, S., Thomas, S. W., et al. (2019) · Advanced Materials · doi:10.1002/adma.201805921 · Cited by 627
Functional Fibers and Fabrics for Soft Robotics, Wearables, and Human–Robot Interface
Xiong, J., Chen, J., & Lee, P. S. (2021) · Advanced Materials · doi:10.1002/adma.202002640 · Cited by 627
Seyedin, S., Uzun, S., Levitt, A., Anasori, B., Dion, G., Gogotsi, Y., & Razal, J. M. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201910504 · Cited by 557
Duan, L., D'hooge, D. R., & Cardon, L. (2020) · Progress in Materials Science · doi:10.1016/j.pmatsci.2019.100617 · Cited by 554
Metadata
- Authors
- Foroughi, J., Spinks, G. M., Aziz, S., Mirabedini, A., Jeiranikhameneh, A., Wallace, G. G., Kozlov, M. E., & Baughman, R. H.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-09-15
- Volume
- 10
- Issue
- 10
- Pages
- 9129-9135
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2512206117
- Cited by
- 229
- References
- 1
- FWCI
- 12.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.