The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Enriching Nanoparticles via Acoustofluidics
Open accessAbstract
Focusing and enriching submicrometer and nanometer scale objects is of great importance for many applications in biology, chemistry, engineering, and medicine. Here, we present an acoustofluidic chip that can generate single vortex acoustic streaming inside a glass capillary through using low-power acoustic waves (only 5 V is required). The single vortex acoustic streaming that is generated, in conjunction with the acoustic radiation force, is able to enrich submicrometer- and nanometer-sized particles in a small volume. Numerical simulations were used to elucidate the mechanism of the single vortex formation and were verified experimentally, demonstrating the focusing of silica and polystyrene particles ranging in diameter from 80 to 500 nm. Moreover, the acoustofluidic chip was used to conduct an immunoassay in which nanoparticles that captured fluorescently labeled biomarkers were concentrated to enhance the emitted signal. With its advantages in simplicity, functionality, and power consumption, the acoustofluidic chip we present here is promising for many point-of-care applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cell patterning with a heptagon acoustic tweezer – application in neurite guidance
Gesellchen, F., Bernassau, A. L., Déjardin, T., Cumming, D. R. S., & Riehle, M. O. (2014) · Lab Chip · doi:10.1039/c4lc00436a · Cited by 98
Cited by
Field-Free Isolation of Exosomes from Extracellular Vesicles by Microfluidic Viscoelastic Flows
Liu, C., Guo, J., Tian, F., Yang, N., Yan, F., Ding, Y., Wei, J., Hu, G., Nie, G., & Sun, J. (2017) · ACS Nano · doi:10.1021/acsnano.7b02277 · Cited by 471
Lin, S., Yu, Z., Chen, D., Wang, Z., Miao, J., Li, Q., Zhang, D., Song, J., & Cui, D. (2020) · Small · doi:10.1002/smll.201903916 · Cited by 353
Zhang, P., Bachman, H., Ozcelik, A., & Huang, T. J. (2020) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-090919-102205 · Cited by 316
Self-citationAcoustofluidics for biomedical applications
Rufo, J., Cai, F., Friend, J., Wiklund, M., & Huang, T. J. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00109-7 · Cited by 305
Self-citationMicro/nano acoustofluidics: materials, phenomena, design, devices, and applications
Connacher, W., Zhang, N., Huang, A., Mei, J., Zhang, S., Gopesh, T., & Friend, J. (2018) · Lab on a Chip · doi:10.1039/c8lc00112j · Cited by 269
Metadata
- Authors
- Mao, Z., Li, P., Wu, M., Bachman, H., Mesyngier, N., Guo, X., Liu, S., Costanzo, F., & Huang, T. J.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-01-09
- Volume
- 11
- Issue
- 1
- Pages
- 603-612
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2571341481
- Cited by
- 169
- References
- 1
- FWCI
- 8.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enriching Nanoparticles via Acoustofluidics. https://app.cochat.ai/papers/10.1021/acsnano.6b06784
- The paper
- Mao, Z., Li, P., Wu, M., Bachman, H., Mesyngier, N., Guo, X., Liu, S., Costanzo, F., & Huang, T. J. (2017). Enriching Nanoparticles via Acoustofluidics. ACS Nano. https://doi.org/10.1021/acsnano.6b06784
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.