Suppression of Frost Nucleation Achieved Using the Nanoengineered Integral Humidity Sink Effect
Abstract
Inhibition of frost formation is important for increasing efficiency of refrigeration systems and heat exchangers, as well as for preventing the rapid icing over of water-repellant coatings that are designed to prevent accumulation of rime and glaze. From a thermodynamic point of view, this task can be achieved by either increasing hydrophobicity of the surface or decreasing the concentration of water vapor above it. The first approach has been studied in depth, but so far has not yielded a robust solution to the problem of frost formation. In this work, we systematically explore how frost growth can be inhibited by controlling water vapor concentration using bilayer coatings with a porous exterior covering a hygroscopic liquid-infused layer. We lay the theoretical foundation and provide experimental validation of the mass transport mechanism that governs the integral humidity sink effect based on this coating platform as well as reveal intriguing sizing effects about this system. We show that the concentration profile above periodically spaced pores is governed by the sink and source concentrations and two geometrical parameters: the nondimensional pore size and the ratio of the pore spacing to the boundary layer thickness. We demonstrate that when the ratio of the pore spacing to the boundary layer thickness vanishes, as for the nanoporous bilayer coatings, the entire surface concentration becomes uniform and equal to the concentration set by the hygroscopic liquid. In other words, the surface concentration becomes completely independent of the nanopore size. We identified the threshold geometrical parameters for this condition and show that it can lead to a 65 K decrease in the nucleation onset surface temperature below the dew point. With this fundamental insight, we use bilayer coatings to nanoengineer the integral humidity sink effect to provide extreme antifrosting performance with up to a 2 h delay in nucleation onset at 263 K. The nanoporous bilayer coatings can be designed to combine optimal antifrosting functionality with a superhydrophobic water repelling exterior to provide coatings that can robustly prevent frost, rime, and glaze accumulation. By minimizing the required amount of antifreeze, this anti-icing method can have minimal operational cost and environmental impact.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Surfaces coupled with hygroscopic liquid can effectively delay frost formation based on the humidity sink effect.
“surfaces coupled with hygroscopic liquid can also effectively delay frost formation based on the humidity sink effect.”
From Frosting mechanism and behaviors on surfaces with simple geometries: A state-of-the-art literature review (2022) · cites this paper as [114]
The ability to delay frosting may be decreased as the hygroscopic liquid becomes diluted.
“the ability to delay frosting may be decreased as the hygroscopic liquid becomes diluted [114,115].”
From Frosting mechanism and behaviors on surfaces with simple geometries: A state-of-the-art literature review (2022) · cites this paper as [114]
Cites
A study of frost growth and densification on flat surfaces
Hermes, C. J. L., Piucco, R. O., Barbosa, J. R., & Melo, C. (2009) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2008.10.006 · Cited by 257 · see citing works
A fundamental understanding of factors affecting frost nucleation
Na, B., & Webb, R. L. (2003) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(03)00194-7 · Cited by 225 · see citing works
Huang, L., Liu, Z., Liu, Y., Gou, Y., & Wang, J. (2009) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2009.06.002 · Cited by 108 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Condensation frosting and passive anti-frosting
Yang, S., Wu, C., Zhao, G., Sun, J., Yao, X., Ma, X., & Wang, Z. (2021) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2021.100474 · Cited by 92 · see citing works
Zhang, L., Song, M., Deng, S., Shen, J., & Dang, C. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.118984 · Cited by 83 · see citing works
Dynamic Defrosting on Superhydrophobic and Biphilic Surfaces
Gurumukhi, Y., Chavan, S., Sett, S., Boyina, K., Ramesh, S., Sokalski, P., Fortelka, K., Lira, M., Park, D., Chen, J.-Y., et al. (2020) · Matter · doi:10.1016/j.matt.2020.06.029 · Cited by 73 · see citing works
- Authors
- Sun, X., & Rykaczewski, K.
- Affiliations
- Arizona State University (US)
- Corresponding author
- Rykaczewski, Konrad
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-12-29
- Volume
- 11
- Issue
- 1
- Pages
- 906-917
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2566461453
- Cited by
- 67
- References
- 3
- Citations by year
- 2026: 7 · 2025: 8 · 2024: 6 · 2023: 5 · 2022: 7 · 2021: 8 · 2020: 6 · 2019: 8 · 2018: 8 · 2017: 4
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- ACS Nano (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Arizona State University
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Surface Modification and Superhydrophobicity
- Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › nanoparticles nucleation surface interactions
- Keywords
- mass transfer, pore size effects, boundary layer thickness, superhydrophobic surfaces, anti-icing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review