Cited by 67Icing and De-icing TechnologiesSurface Modification and Superhydrophobicitynanoparticles nucleation surface interactions

Suppression of Frost Nucleation Achieved Using the Nanoengineered Integral Humidity Sink Effect

Sun, Xiaoda, Rykaczewski, Konrad·2017·ACS Nano

Abstract

Inhibition of frost formation is important for increasing efficiency of refrigeration systems and heat exchangers, as well as for preventing the rapid icing over of water-repellant coatings that are designed to prevent accumulation of rime and glaze. From a thermodynamic point of view, this task can be achieved by either increasing hydrophobicity of the surface or decreasing the concentration of water vapor above it. The first approach has been studied in depth, but so far has not yielded a robust solution to the problem of frost formation. In this work, we systematically explore how frost growth can be inhibited by controlling water vapor concentration using bilayer coatings with a porous exterior covering a hygroscopic liquid-infused layer. We lay the theoretical foundation and provide experimental validation of the mass transport mechanism that governs the integral humidity sink effect based on this coating platform as well as reveal intriguing sizing effects about this system. We show that the concentration profile above periodically spaced pores is governed by the sink and source concentrations and two geometrical parameters: the nondimensional pore size and the ratio of the pore spacing to the boundary layer thickness. We demonstrate that when the ratio of the pore spacing to the boundary layer thickness vanishes, as for the nanoporous bilayer coatings, the entire surface concentration becomes uniform and equal to the concentration set by the hygroscopic liquid. In other words, the surface concentration becomes completely independent of the nanopore size. We identified the threshold geometrical parameters for this condition and show that it can lead to a 65 K decrease in the nucleation onset surface temperature below the dew point. With this fundamental insight, we use bilayer coatings to nanoengineer the integral humidity sink effect to provide extreme antifrosting performance with up to a 2 h delay in nucleation onset at 263 K. The nanoporous bilayer coatings can be designed to combine optimal antifrosting functionality with a superhydrophobic water repelling exterior to provide coatings that can robustly prevent frost, rime, and glaze accumulation. By minimizing the required amount of antifreeze, this anti-icing method can have minimal operational cost and environmental impact.

Integrity signals

Registry

Crossref · 10.1021/acsnano.6b07505

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Sun, X., & Rykaczewski, K.
Affiliations
Arizona State University (US)
Corresponding author
Rykaczewski, Konrad
Venue
ACS Nano
Published
2016-12-29
Volume
11
Issue
1
Pages
906-917
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W2566461453
Cited by
67
References
3
Citations by year
2026: 7 · 2025: 8 · 2024: 6 · 2023: 5 · 2022: 7 · 2021: 8 · 2020: 6 · 2019: 8 · 2018: 8 · 2017: 4
FWCI
8.15
Type
journal article
Language
en
Open access
closed
Locations
  • ACS Nano (publishedVersion)
  • PubMed (publishedVersion)
Funders
Arizona State University
Topics
  • Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Surface Modification and Superhydrophobicity
  • Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › nanoparticles nucleation surface interactions
Keywords
mass transfer, pore size effects, boundary layer thickness, superhydrophobic surfaces, anti-icing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review