The DOI matches its Crossref record.
One-Dimensional Luminous Nanorods Featuring Tunable Persistent Luminescence for Autofluorescence-Free Biosensing
Abstract
Persistent luminescence nanoparticles (PLNPs), which can remain luminescent after cessation of excitation, have emerged as important materials in biomedicine due to their special ability to eliminate tissue autofluorescence. Even though significant advances have been made in bioimaging, studies on controlled synthesis of PLNPs with tunable properties are lacking. Until now, only a few studies have reported the synthesis of quasi-spherical ZnGa 2 O 4:Cr PLNPs, and direct synthesis of PLNPs with other shapes and chemical compositions has not been reported. Herein, we report the direct synthesis of Zn 2 GeO 4:Mn (ZGO:Mn) persistent luminescence nanorods (NRs). The length and persistent luminescence of ZGO:Mn NRs can be fine-tuned by simply changing the pH of the hydrothermal reaction system. Moreover, ZGO:Mn NRs exhibit rapid growth rate, and NRs with strong persistent luminescence can be obtained within 30 min of hydrothermal treatment. Aptamer-guided ZGO:Mn bioprobes were further constructed and applied to serum lysozyme analysis. Serum samples from patients with lung cancer, gastric cancer, and colorectal cancer were collected, and the concentrations of lysozyme in these samples were determined. Since the bioprobes displayed long persistent luminescence, serum autofluorescence interference was completely eliminated. The lysozyme quantification results were in good agreement with those obtained using a clinical method, suggesting the good potential of the bioprobes in the analysis of clinical samples. The developed ZGO:Mn NRs possess tunable length and persistent luminescence, and they are ideal for eliminating autofluorescence interference in biosensing, making them valuable in research areas such as studying the functions of biomolecules and monitoring of molecular/cellular networks in their native contexts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Molecular Probes for Autofluorescence-Free Optical Imaging
Jiang, Y., & Pu, K. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00506 · Cited by 426
Two Are Better Than One: A Design Principle for Ultralong‐Persistent Luminescence of Pure Organics
Alam, P., Leung, N. L. C., Liu, J., Cheung, T. S., Zhang, X., He, Z., Kwok, R. T. K., Lam, J. W. Y., Sung, H. H. Y., Williams, I. D., et al. (2020) · Advanced Materials · doi:10.1002/adma.202001026 · Cited by 288
Huang, K., Le, N., Wang, J. S., Huang, L., Zeng, L., Xu, W., Li, Z., Li, Y., & Han, G. (2022) · Advanced Materials · doi:10.1002/adma.202107962 · Cited by 258
Self-citationTan, H., Wang, T., Shao, Y., Yu, C., & Hu, L. (2019) · Frontiers in Chemistry · doi:10.3389/fchem.2019.00387 · Cited by 59
Metadata
- Authors
- Wang, J., Ma, Q., Zheng, W., Liu, H., Yin, C., Wang, F., Chen, X., Yuan, Q., & Tan, W.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-07-05
- Volume
- 11
- Issue
- 8
- Pages
- 8185-8191
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2733425144
- Cited by
- 193
- References
- 0
- FWCI
- 6.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.