The DOI matches its Crossref record.
Endogenous Catalytic Generation of O2 Bubbles for In Situ Ultrasound-Guided High Intensity Focused Ultrasound Ablation
Abstract
High intensity focused ultrasound (HIFU) surgery generally suffers from poor precision and low efficiency in clinical application, especially for cancer therapy. Herein, a multiscale hybrid catalytic nanoreactor (catalase@MONs, abbreviated as C@M) has been developed as a tumor-sensitive contrast and synergistic agent (C&SA) for ultrasound-guided HIFU cancer surgery, by integrating dendritic-structured mesoporous organosilica nanoparticles (MONs) and catalase immobilized in the large open pore channels of MONs. Such a hybrid nanoreactor exhibited sensitive catalytic activity toward H 2 O 2, facilitating the continuous O 2 gas generation in a relatively mild manner even if incubated with 10 μM H 2 O 2, which finally led to enhanced ablation in the tissue-mimicking PAA gel model after HIFU exposure mainly resulting from intensified cavitation effect. The C@M nanoparticles could be accumulated within the H 2 O 2 -enriched tumor region through enhanced permeability and retention effect, enabling durable contrast enhancement of ultrasound imaging, and highly efficient tumor ablation under relatively low power of HIFU exposure in vivo . Very different from the traditional perfluorocarbon-based C&SA, such an on-demand catalytic nanoreactor could realize the accurate positioning of tumor without HIFU prestimulation and efficient HIFU ablation with a much safer power output, which is highly desired in clinical HIFU application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Yang, B., Chen, Y., & Shi, J. (2019) · Advanced Materials · doi:10.1002/adma.201901778 · Cited by 601
Self-citationUltrasound‐Activated Sensitizers and Applications
Lin, X., Song, J., Chen, X., & Yang, H. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201906823 · Cited by 501
Theranostic Fluorescent Probes
Sharma, A., Verwilst, P., Li, M., Ma, D., Singh, N., Yoo, J., Kim, Y., Yang, Y., Zhu, J.-H., Huang, H., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00778 · Cited by 499
Advances and perspectives in organic sonosensitizers for sonodynamic therapy
Xing, X., Zhao, S., Xu, T., Huang, L., Zhang, Y., Lan, M., Lin, C., Zheng, X., & Wang, P. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214087 · Cited by 334
Stimuli‐Responsive Nanoparticles for Controlled Drug Delivery in Synergistic Cancer Immunotherapy
Zhang, J., Lin, Y., Lin, Z., Wei, Q., Qian, J., Ruan, R., Jiang, X., Hou, L., Song, J., Ding, J., et al. (2022) · Advanced Science · doi:10.1002/advs.202103444 · Cited by 292
Metadata
- Authors
- Liu, T., Zhang, N., Wang, Z., Wu, M., Chen, Y., Ma, M., Chen, H., & Shi, J.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-08-16
- Volume
- 11
- Issue
- 9
- Pages
- 9093-9102
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2744476812
- Cited by
- 163
- References
- 0
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Endogenous Catalytic Generation of O2 Bubbles for In Situ Ultrasound-Guided High Intensity Focused Ultrasound Ablation. https://app.cochat.ai/papers/10.1021/acsnano.7b03772
- The paper
- Liu, T., Zhang, N., Wang, Z., Wu, M., Chen, Y., Ma, M., Chen, H., & Shi, J. (2017). Endogenous Catalytic Generation of O2 Bubbles for In Situ Ultrasound-Guided High Intensity Focused Ultrasound Ablation. ACS Nano. https://doi.org/10.1021/acsnano.7b03772
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.