The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Accelerating Palladium Nanowire H2 Sensors Using Engineered Nanofiltration
Abstract
The oxygen, O 2, in air interferes with the detection of H 2 by palladium (Pd)-based H 2 sensors, including Pd nanowires (NWs), depressing the sensitivity and retarding the response/recovery speed in air—relative to N 2 or Ar. Here, we describe the preparation of H 2 sensors in which a nanofiltration layer consisting of a Zn metal–organic framework (MOF) is assembled onto Pd NWs. Polyhedron particles of Zn-based zeolite imidazole framework (ZIF-8) were synthesized on lithographically patterned Pd NWs, leading to the creation of ZIF-8/Pd NW bilayered H 2 sensors. The ZIF-8 filter has many micropores (0.34 nm for gas diffusion) which allows for the predominant penetration of hydrogen molecules with a kinetic diameter of 0.289 nm, whereas relatively larger gas molecules including oxygen (0.345 nm) and nitrogen (0.364 nm) in air are effectively screened, resulting in superior hydrogen sensing properties. Very importantly, the Pd NWs filtered by ZIF-8 membrane (Pd NWs@ZIF-8) reduced the H 2 response amplitude slightly (Δ R / R 0 = 3.5% to 1% of H 2 versus 5.9% for Pd NWs) and showed 20-fold faster recovery (7 s to 1% of H 2 ) and response (10 s to 1% of H 2 ) speed compared to that of pristine Pd NWs (164 s for response and 229 s for recovery to 1% of H 2 ). These outstanding results, which are mainly attributed to the molecular sieving and acceleration effect of ZIF-8 covered on Pd NWs, rank highest in H 2 sensing speed among room-temperature Pd-based H 2 sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metal-organic framework materials as catalysts
Lee, J., Farha, O. K., Roberts, J., Scheidt, K. A., Nguyen, S. T., & Hupp, J. T. (2009) · Chemical Society Reviews · doi:10.1039/b807080f · Cited by 7,969
Cleaning the air and improving health with hydrogen fuel-cell vehicles
Jacobson, M. Z., Colella, W. G., & Golden, D. M. (2005) · Science · doi:10.1126/science.1109157 · Cited by 1,023
Cited by
Darmadi, I., Nugroho, F. A. A., & Langhammer, C. (2020) · ACS Sensors · doi:10.1021/acssensors.0c02019 · Cited by 382
Chemiresistive Hydrogen Sensors: Fundamentals, Recent Advances, and Challenges
Koo, W.-T., Cho, H.-J., Kim, D.-H., Kim, Y. H., Shin, H., Penner, R. M., & Kim, I.-D. (2020) · ACS Nano · doi:10.1021/acsnano.0c05307 · Cited by 379
Self-citationMetal–polymer hybrid nanomaterials for plasmonic ultrafast hydrogen detection
Nugroho, F. A. A., Darmadi, I., Cusinato, L., Susarrey-Arce, A., Schreuders, H., Bannenberg, L. J., da Silva Fanta, A. B., Kadkhodazadeh, S., Wagner, J. B., Antosiewicz, T. J., et al. (2019) · Nature Materials · doi:10.1038/s41563-019-0325-4 · Cited by 365
Metal–organic frameworks and their derivatives for electrically-transduced gas sensors
Yao, M.-S., Li, W.-H., & Xu, G. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213479 · Cited by 264
Metadata
- Authors
- Koo, W.-T., Qiao, S., Ogata, A. F., Jha, G., Jang, J.-S., Chen, V. T., Kim, I.-D., & Penner, R. M.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-08-28
- Volume
- 11
- Issue
- 9
- Pages
- 9276-9285
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2746288040
- Cited by
- 249
- References
- 2
- FWCI
- 8.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accelerating Palladium Nanowire H2 Sensors Using Engineered Nanofiltration. https://app.cochat.ai/papers/10.1021/acsnano.7b04529
- The paper
- Koo, W.-T., Qiao, S., Ogata, A. F., Jha, G., Jang, J.-S., Chen, V. T., Kim, I.-D., & Penner, R. M. (2017). Accelerating Palladium Nanowire H2 Sensors Using Engineered Nanofiltration. ACS Nano. https://doi.org/10.1021/acsnano.7b04529
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.