The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
3D Synergistical MXene/Reduced Graphene Oxide Aerogel for a Piezoresistive Sensor
Abstract
A piezoresistive sensor based on ultralight and superelastic aerogel is reported to fabricate MXene/reduced graphene oxide (MX/rGO) hybrid 3D structures and utilize their pressure-sensitive characteristics. The MX/rGO aerogel not only combines the rGO’s large specific surface area and the MXene’s (Ti 3 C 2 T x ) high conductivity but also exhibits rich porous structure, which leads to performance better than that of single-component rGO or MXene in terms of the pressure sensor. The large nanosheets of rGO can prevent the poor oxidization of MXene by wrapping MXene inside the aerogel. More importantly, the piezoresistive sensor based on the MX/rGO aerogel shows extremely high sensitivity (22.56 kPa –1 ), fast response time (<200 ms), and good stability over 10 000 cycles. The piezoresistive sensor based on the MX/rGO hybrid 3D aerogel can easily capture the signal below 10 Pa, thus clearly testing the pulse of an adult at random. Based on its superior performance, it also demonstrates potential applications in measuring pressure distribution, distinguishing subtle strain, and monitoring healthy activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Synthesis of Graphene Aerogel with High Electrical Conductivity
Worsley, M. A., Pauzauskie, P. J., Olson, T. Y., Biener, J., Satcher, J. H., & Baumann, T. F. (2010) · Journal of the American Chemical Society · doi:10.1021/ja1072299 · Cited by 1,216
Park, J., Lee, Y., Hong, J., Ha, M., Jung, Y.-D., Lim, H., Kim, S. Y., & Ko, H. (2014) · ACS Nano · doi:10.1021/nn500441k · Cited by 915
Electronic Skin with Multifunction Sensors Based on Thermosensation
Zhao, S., & Zhu, R. (2017) · Advanced Materials · doi:10.1002/adma.201606151 · Cited by 273
Cited by
Cao, M.-S., Cai, Y.-Z., He, P., Shu, J.-C., Cao, W.-Q., & Yuan, J. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.11.051 · Cited by 979
Jiang, X., Kuklin, A. V., Baev, A., Ge, Y., Ågren, H., Zhang, H., & Prasad, P. N. (2020) · Physics Reports · doi:10.1016/j.physrep.2019.12.006 · Cited by 914
Self-citationZhao, S., Zhang, H.-B., Luo, J.-Q., Wang, Q.-W., Xu, B., Hong, S., & Yu, Z.-Z. (2018) · ACS Nano · doi:10.1021/acsnano.8b05739 · Cited by 893
Self-citationRecent developments in emerging two-dimensional materials and their applications
Khan, K., Tareen, A. K., Aslam, M., Wang, R., Zhang, Y., Mahmood, A., Ouyang, Z., Zhang, H., & Guo, Z. (2020) · Journal of Materials Chemistry C · doi:10.1039/c9tc04187g · Cited by 886
Self-citationTi3C2TX MXene for Sensing Applications: Recent Progress, Design Principles, and Future Perspectives
Pei, Y., Zhang, X., Hui, Z., Zhou, J., Huang, X., Sun, G., & Huang, W. (2021) · ACS Nano · doi:10.1021/acsnano.1c00248 · Cited by 799
Metadata
- Authors
- Ma, Y., Yue, Y., Zhang, H., Cheng, F., Zhao, W., Rao, J., Luo, S., Wang, J., Jiang, X., Liu, Z., Liu, N., & Gao, Y.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-04-02
- Volume
- 12
- Issue
- 4
- Pages
- 3209-3216
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2795952901
- Cited by
- 857
- References
- 4
- FWCI
- 32.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.