The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Charge-Switchable Nanozymes for Bioorthogonal Imaging of Biofilm-Associated Infections
Open accessAbstract
Early detection of biofilms is crucial for limiting infection-based damage. Imaging these biofilms is challenging: conventional imaging agents are unable to penetrate the dense matrix of the biofilm, and many imaging agents are susceptible to false positive/negative responses due to phenotypical mutations of the constituent microbes. We report the creation of pH-responsive nanoparticles with embedded transition metal catalysts (nanozymes) that effectively target the acidic microenvironment of biofilms. These pH-switchable nanozymes generate imaging agents through bioorthogonal activation of profluorophores inside biofilms. The specificity of these nanozymes for imaging biofilms in complex biosystems was demonstrated using coculture experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Persister cells, dormancy and infectious disease
Lewis, K. (2007) · Nature Reviews Microbiology · doi:10.1038/nrmicro1557 · Cited by 2,052
Pseudomonas aeruginosa Displays Multiple Phenotypes during Development as a Biofilm
Sauer, K., Camper, A. K., Ehrlich, G. D., Costerton, J. W., & Davies, D. G. (2002) · Journal of Bacteriology · doi:10.1128/jb.184.4.1140-1154.2002 · Cited by 1,691
Anderl, J. N., Franklin, M. J., & Stewart, P. S. (2000) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.44.7.1818-1824.2000 · Cited by 958
Cited by
Nanomaterials with enzyme-like characteristics (nanozymes): next-generation artificial enzymes (II)
Wu, J., Wang, X., Wang, Q., Lou, Z., Li, S., Zhu, Y., Qin, L., & Wei, H. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00457a · Cited by 4,108
Hu, D., Deng, Y., Jia, F., Jin, Q., & Ji, J. (2020) · ACS Nano · doi:10.1021/acsnano.9b05493 · Cited by 489
An overview of the use of nanozymes in antibacterial applications
Mei, L., Zhu, S., Liu, Y., Yin, W., Gu, Z., & Zhao, Y. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.129431 · Cited by 369
Delivery of drugs, proteins, and nucleic acids using inorganic nanoparticles
Luther, D. C., Huang, R., Jeon, T., Zhang, X., Lee, Y.-W., Nagaraj, H., & Rotello, V. M. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.06.020 · Cited by 364
Self-citationNitrogen-Doped Carbon Nanomaterials as Highly Active and Specific Peroxidase Mimics
Hu, Y., Gao, X. J., Zhu, Y., Muhammad, F., Tan, S., Cao, W., Lin, S., Jin, Z., Gao, X., & Wei, H. (2018) · Chemistry of Materials · doi:10.1021/acs.chemmater.8b02726 · Cited by 316
Metadata
- Authors
- Gupta, A., Das, R., Yesilbag Tonga, G., Mizuhara, T., & Rotello, V. M.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-12-21
- Volume
- 12
- Issue
- 1
- Pages
- 89-94
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2773048727
- Cited by
- 194
- References
- 3
- FWCI
- 6.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.