The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Biomembrane-Modified Field Effect Transistors for Sensitive and Quantitative Detection of Biological Toxins and Pathogens
Abstract
The efforts of detecting bioactive targets with complex, dynamic, and unknown molecular profiles have inspired the development of various biosensor platforms. Herein, we report a cell-membrane-modified field effect transistor (FET) as a function-based nanosensor for the detection and quantitative measurement of numerous toxins and biological samples. By coating carbon nanotube FETs with natural red blood cell membranes, the resulting biomimetic nanosensor can selectively interact with and absorb broad-spectrum hemolytic toxins regardless of their molecular structures. Toxin-biomembrane interactions alter the local charge distribution at the FET surface in an ultrasensitive and concentration-dependent manner, resulting in a detection limit down to the femtomolar (fM) range. Accurate and quantitative measurements are enabled via a built-in calibration mechanism of the sensor, which overcomes batch-to-batch fabrication variations, and are demonstrated using three distinct toxins and various complex bacterial supernatants. The measured signals of bacterium-secreted proteins correlate linearly with the actual bacterial numbers, making the biosensor a nontraditional approach to rapidly detecting bacterial concentrations without a need to count bacterial colonies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Cited by
Low‐Dimensional Metal Halide Perovskite Photodetectors
Wang, H., Li, S., Liu, X., Shi, Z., Fang, X., & He, J. (2021) · Advanced Materials · doi:10.1002/adma.202003309 · Cited by 574
Near-infrared luminescence high-contrast in vivo biomedical imaging
Chen, Y., Wang, S., & Zhang, F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00002-8 · Cited by 566
Self-citationDoping and ion substitution in colloidal metal halide perovskite nanocrystals
Lu, C.-H., Biesold-McGee, G. V., Liu, Y., Kang, Z., & Lin, Z. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00790c · Cited by 484
Surface Chemistry Engineering of Perovskite Quantum Dots: Strategies, Applications, and Perspectives
Bai, Y., Hao, M., Ding, S., Chen, P., & Wang, L. (2022) · Advanced Materials · doi:10.1002/adma.202105958 · Cited by 394
From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S. (2021) · ACS Nano · doi:10.1021/acsnano.0c06688 · Cited by 359
Metadata
- Authors
- Gong, H., Chen, F., Huang, Z., Gu, Y., Zhang, Q., Chen, Y., Zhang, Y., Zhuang, J., Cho, Y.-K., Fang, R. H., Gao, W., Xu, S., & Zhang, L.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-03-04
- Volume
- 13
- Issue
- 3
- Pages
- 3714-3722
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2919299577
- Cited by
- 248
- References
- 1
- FWCI
- 13.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biomembrane-Modified Field Effect Transistors for Sensitive and Quantitative Detection of Biological Toxins and Pathogens. https://app.cochat.ai/papers/10.1021/acsnano.9b00911
- The paper
- Gong, H., Chen, F., Huang, Z., Gu, Y., Zhang, Q., Chen, Y., Zhang, Y., Zhuang, J., Cho, Y.-K., Fang, R. H., Gao, W., Xu, S., & Zhang, L. (2019). Biomembrane-Modified Field Effect Transistors for Sensitive and Quantitative Detection of Biological Toxins and Pathogens. ACS Nano. https://doi.org/10.1021/acsnano.9b00911
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.