The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Rewritable, Printable Conducting Liquid Metal Hydrogel
Abstract
The development of high-performance printable electrical circuits, particularly based on liquid metals, is fundamental for device interconnection in flexible electronics, motivating numerous attempts to develop a variety of alloys and their composites. Despite their great potential, rewritable and printable electronic circuits based on liquid metals are still manufactured on demand. In this study, we demonstrate liquid metal-based hydrogels suitable for rewritable, printable electrical circuits. Our liquid metal hydrogels are based on sedimentation-induced composites of eutectic gallium–indium (EGaIn) particles in poly(ethylene glycol) diacrylate (PEGDA). The EGaIn particles are vertically phase-segregated in the PEGDA. When a composite surface with high EGaIn content is gently scratched, the surface covering PEGDA is removed, followed by the rupture of the native oxide layers of the particles, and the exposed EGaIn becomes conductive. The subsequent water-driven swelling of PEGDA on the scratched surface completely erases the conductive circuit, causing the system to reset. Our friction-responsive liquid metal hydrogel exhibits writing–erasing endurance for 20 cycles, with a dramatic change in the electrical resistance from metal (∼1 Ω) to insulator (∼10 7 Ω). By employing surface friction pen printing, we demonstrate mechanically flexible, rewritable, printable electrical conductors suitable for displays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rahman, M. T., Barikbin, Z., Badruddoza, A. Z. M., Doyle, P. S., & Khan, S. A. (2013) · Langmuir · doi:10.1021/la401613w · Cited by 76
Cited by
Development of Conductive Hydrogels for Fabricating Flexible Strain Sensors
Li, G., Li, C., Li, G., Yu, D., Song, Z., Wang, H., Liu, X., Liu, H., & Liu, W. (2022) · Small · doi:10.1002/smll.202101518 · Cited by 509
Multifunctional conductive hydrogels and their applications as smart wearable devices
Chen, Z., Chen, Y., Hedenqvist, M. S., Chen, C., Cai, C., Li, H., Liu, H., & Fu, J. (2021) · Journal of Materials Chemistry B · doi:10.1039/d0tb02929g · Cited by 323
Shaping a Soft Future: Patterning Liquid Metals
Ma, J., Krisnadi, F., Vong, M. H., Kong, M., Awartani, O. M., & Dickey, M. D. (2023) · Advanced Materials · doi:10.1002/adma.202205196 · Cited by 311
A self-healing electrically conductive organogel composite
Zhao, Y., Ohm, Y., Liao, J., Luo, Y., Cheng, H.-Y., Won, P., Roberts, P., Carneiro, M. R., Islam, M. F., Ahn, J. H., et al. (2023) · Nature Electronics · doi:10.1038/s41928-023-00932-0 · Cited by 292
A Review of Conductive Hydrogel‐Based Wearable Temperature Sensors
Mo, F., Zhou, P., Lin, S., Zhong, J., & Wang, Y. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202401503 · Cited by 187
Metadata
- Authors
- Park, J.-E., Kang, H. S., Baek, J., Park, T. H., Oh, S., Lee, H., Koo, M., & Park, C.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-08-13
- Volume
- 13
- Issue
- 8
- Pages
- 9122-9130
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2967526478
- Cited by
- 173
- References
- 1
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.