The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
MXene–Graphene Field-Effect Transistor Sensing of Influenza Virus and SARS-CoV-2
Open accessAbstract
An MXene-graphene field-effect transistor (FET) sensor for both influenza virus and 2019-nCoV sensing was developed and characterized. The developed sensor combines the high chemical sensitivity of MXene and the continuity of large-area high-quality graphene to form an ultra-sensitive virus-sensing transduction material (VSTM). Through polymer linking, we are able to utilize antibody-antigen binding to achieve electrochemical signal transduction when viruses are deposited onto the VSTM surface. The MXene-graphene VSTM was integrated into a microfluidic channel that can directly receive viruses in solution. The developed sensor was tested with various concentrations of antigens from two viruses: inactivated influenza A (H1N1) HA virus ranging from 125 to 250,000 copies/mL and a recombinant 2019-nCoV spike protein ranging from 1 fg/mL to 10 pg/mL. The average response time was about ∼50 ms, which is significantly faster than the existing real-time reverse transcription-polymerase chain reaction method (>3 h). The low limit of detection (125 copies/mL for the influenza virus and 1 fg/mL for the recombinant 2019-nCoV spike protein) has demonstrated the sensitivity of the MXene-graphene VSTM on the FET platform to virus sensing. Especially, the high signal-to-viral load ratio (∼10% change in source-drain current and gate voltage) also demonstrates the ultra-sensitivity of the developed MXene-graphene FET sensor. In addition, the specificity of the sensor was also demonstrated by depositing the inactivated influenza A (H1N1) HA virus and the recombinant 2019-nCoV spike protein onto microfluidic channels with opposite antibodies, producing signal differences that are about 10 times lower. Thus, we have successfully fabricated a relatively low-cost, ultrasensitive, fast-responding, and specific inactivated influenza A (H1N1) and 2019-nCoV sensor with the MXene-graphene VSTM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metallic Ti3C2T x MXene Gas Sensors with Ultrahigh Signal-to-Noise Ratio
Kim, S. J., Koh, H.-J., Ren, C. E., Kwon, O., Maleski, K., Cho, S.-Y., Anasori, B., Kim, C.-K., Choi, Y.-K., Kim, J., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07460 · Cited by 1,699
Cited by
Chaudhary, V., Kaushik, A., Furukawa, H., & Khosla, A. (2022) · ECS Sensors Plus · doi:10.1149/2754-2726/ac5ac6 · Cited by 386
The development of integrated circuits based on two-dimensional materials
Zhu, K., Wen, C., Aljarb, A. A., Xue, F., Xu, X., Tung, V., Zhang, X., Alshareef, H. N., & Lanza, M. (2021) · Nature Electronics · doi:10.1038/s41928-021-00672-z · Cited by 327
Two-Dimensional Field-Effect Transistor Sensors: The Road toward Commercialization
Dai, C., Liu, Y., & Wei, D. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00924 · Cited by 303
Brümmer, L. E., Katzenschlager, S., Gaeddert, M., Erdmann, C., Schmitz, S., Bota, M., Grilli, M., Larmann, J., Weigand, M. A., Pollock, N. R., et al. (2021) · PLOS Medicine · doi:10.1371/journal.pmed.1003735 · Cited by 298
Metadata
- Authors
- Li, Y., Peng, Z., Holl, N. J., Hassan, M. R., Pappas, J. M., Wei, C., Izadi, O. H., Wang, Y., Dong, X., Wang, C., Huang, Y.-W., Kim, D., & Wu, C.
- Venue
- ACS Omega
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-03-02
- Volume
- 6
- Issue
- 10
- Pages
- 6643-6653
- ISSN
- 2470-1343 (ISSN-L)
- OpenAlex
- W3134072313
- Cited by
- 167
- References
- 1
- FWCI
- 9.07
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MXene–Graphene Field-Effect Transistor Sensing of Influenza Virus and SARS-CoV-2. https://app.cochat.ai/papers/10.1021/acsomega.0c05421
- The paper
- Li, Y., Peng, Z., Holl, N. J., Hassan, M. R., Pappas, J. M., Wei, C., Izadi, O. H., Wang, Y., Dong, X., Wang, C., Huang, Y.-W., Kim, D., & Wu, C. (2021). MXene–Graphene Field-Effect Transistor Sensing of Influenza Virus and SARS-CoV-2. ACS Omega. https://doi.org/10.1021/acsomega.0c05421
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.