Octanol–Water Partition Coefficient Measurement by a Simple 1H NMR Method
Open accessThe DOI matches its Crossref record.
Abstract
We describe a simple miniature shake-flask method to measure the octanol–water partition coefficient of an organic compound. Partition between water and octanol is performed in an NMR tube; the aqueous phase is analyzed by 1H NMR spectroscopy using a benchtop low-field NMR instrument. Neither pre-equilibration of solvents nor isolation of the two phases is required. The procedure is fast and easy enough to be used in a students’ laboratory. Scope and limitations as well as possible sources of error are discussed in detail.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sousa, F. M., Lima, L. M. P., Arnarez, C., Pereira, M. M., & Melo, M. N. (2021) · Journal of Chemical Information and Modeling · doi:10.1021/acs.jcim.0c01077 · Cited by 30
Metadata
- Authors
- Cumming, H., & Rücker, C.
- Venue
- ACS Omega
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-09-28
- Volume
- 2
- Issue
- 9
- Pages
- 6244-6249
- ISSN
- 2470-1343 (ISSN-L)
- OpenAlex
- W2757568157
- Cited by
- 179
- References
- 0
- FWCI
- 5.90
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Octanol–Water Partition Coefficient Measurement by a Simple 1H NMR Method. https://app.cochat.ai/papers/10.1021/acsomega.7b01102
- The paper
- Cumming, H., & Rücker, C. (2017). Octanol–Water Partition Coefficient Measurement by a Simple 1H NMR Method. ACS Omega. https://doi.org/10.1021/acsomega.7b01102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.