Simultaneous Removal of Multiple Heavy Metal Ions from River Water Using Ultrafine Mesoporous Magnetite Nanoparticles
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
The exploration of simultaneous removal of co-existing or multiple pollutants from water by the means of nanomaterials paves a new avenue that is free from secondary pollution and inexpensive. In the aquatic environment, river water contains a mixture of ions, which can influence the adsorption process. In this respect, removing heavy metal ions becomes a true challenge. Here, four heavy metal ions, namely, Pb2+, Cd2+, Cu2+, and Ni2+, have been successfully removed simultaneously from river water using ultrafine mesoporous magnetite (Fe3O4) nanoparticles (UFMNPs) based on the affinity of these metal ions toward the UFMNP surfaces as well as their unique mesoporous structure, promoting the easy adsorption. The individual removal efficiencies of Pb2+, Cd2+, Cu2+, and Ni2+ ions from river water were 98, 87, 90, and 78%, respectively, whereas the removal efficiencies of the mixed Pb2+, Cd2+, Cu2+, and Ni2+ ions were 86, 80, 84, and 54%, respectively, in the same river water. Thus, the data clearly indicate the complex removal of heavy metal ions in multi-ion systems. This study has demonstrated the huge potential of UFMNPs to be effective for their use in wastewater treatment, especially to simultaneously remove multiple heavy metal ions from aqueous media.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Removal of heavy metal ions from wastewaters: A review
Fu, F., & Wang, Q. (2011) · Journal of Environmental Management · doi:10.1016/j.jenvman.2010.11.011 · Cited by 8,703
Mesoporous Titania Spheres with Tunable Chamber Stucture and Enhanced Photocatalytic Activity
Li, H., Bian, Z., Zhu, J., Zhang, D., Li, G., Huo, Y., Li, H., & Lu, Y. (2007) · Journal of the American Chemical Society · doi:10.1021/ja072191c · Cited by 1,170
Liu, J.-F., Zhao, Z.-S., & Jiang, G.-B. (2008) · Environmental Science & Technology · doi:10.1021/es800924c · Cited by 1,084
Tea waste as a low cost adsorbent for the removal of Cu and Pb from wastewater
Amarasinghe, B. M. W. P. K., & Williams, R. A. (2007) · Chemical Engineering Journal · doi:10.1016/j.cej.2007.01.016 · Cited by 845
Faraji, M., Yamini, Y., & Rezaee, M. (2010) · Journal of the Iranian Chemical Society · doi:10.1007/bf03245856 · Cited by 755
Rajput, S., Pittman, C. U., & Mohan, D. (2016) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2015.12.008 · Cited by 746
Yantasee, W., Warner, C. L., Sangvanich, T., Addleman, R. S., Carter, T. G., Wiacek, R. J., Fryxell, G. E., Timchalk, C., & Warner, M. G. (2007) · Environmental Science & Technology · doi:10.1021/es0705238 · Cited by 688
Rapid removal and recovery of Pb(II) from wastewater by magnetic nanoadsorbents
Nassar, N. N. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.08.069 · Cited by 596
Multivariate statistical analysis of heavy metals in street dust of Baoji, NW China
Lu, X., Wang, L., Li, L. Y., Lei, K., Huang, L., & Dan, K. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.09.001 · Cited by 574
Preparation and application of magnetic Fe3O4 nanoparticles for wastewater purification
Shen, Y. F., Tang, J., Nie, Z. H., Wang, Y. D., Ren, Y., & Zuo, L. (2009) · Separation and Purification Technology · doi:10.1016/j.seppur.2009.05.020 · Cited by 570
Magnetic Chitosan Nanocomposites: A Useful Recyclable Tool for Heavy Metal Ion Removal
Liu, X., Hu, Q., Fang, Z., Zhang, X., & Zhang, B. (2009) · Langmuir · doi:10.1021/la802754t · Cited by 532
Fan, T., Liu, Y., Feng, B., Zeng, G., Yang, C., Zhou, M., Zhou, H., Tan, Z., & Wang, X. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.03.038 · Cited by 479
Rapid, Selective Heavy Metal Removal from Water by a Metal–Organic Framework/Polydopamine Composite
Sun, D. T., Peng, L., Reeder, W. S., Moosavi, S. M., Tiana, D., Britt, D. K., Oveisi, E., & Queen, W. L. (2018) · ACS Central Science · doi:10.1021/acscentsci.7b00605 · Cited by 443
Yuan, P., Liu, D., Fan, M., Yang, D., Zhu, R., Ge, F., Zhu, J., & He, H. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.08.129 · Cited by 380
Kumari, M., Pittman, C. U., & Mohan, D. (2015) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2014.09.012 · Cited by 377
Application of Iron Oxide Nanomaterials for the Removal of Heavy Metals
Dave, P. N., & Chopda, L. V. (2014) · Journal of Nanotechnology · doi:10.1155/2014/398569 · Cited by 305 · cited 1×
“6 Of all of the various treatment technologies, adsorption is one of the techniques generally used due to its cost-e ff ectiveness and fl exibility in design and operation.”
Giraldo, L., Erto, A., & Moreno-Piraján, J. C. (2013) · Adsorption · doi:10.1007/s10450-012-9468-1 · Cited by 284
Heavy metal removal from water by magnetite nanorods
Karami, H. (2013) · Chemical Engineering Journal · doi:10.1016/j.cej.2013.01.022 · Cited by 236 · cited 5×
“7,32 Moreover, at 25 ° C, the solubility product constants of Pb(OH) 2 , Cd(OH) 2 , Cu(OH) 2 , and Ni(OH) 2 are 1.43 × 10 − 20 , 7.20 × 10 − 15 , 2.00 × 10 − 15 , and 5.48 × 10 − 16 , respectively.”
InfluentialLi, J., Zhao, X., Shi, Y., Cai, Y., Mou, S., & Jiang, G. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.12.028 · Cited by 205
Ding, C., Cheng, W., Wang, X., Wu, Z., Sun, Y., Chen, C., Wang, X., & Yu, S. (2016) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2016.04.002 · Cited by 199
Yang, L., Chen, Z., Cui, D., Luo, X., Liang, B., Yang, L., Liu, T., Wang, A., & Luo, S. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.11.099 · Cited by 167
Reduction of Hg(II) to Hg(0) by Magnetite
Wiatrowski, H. A., Das, S., Kukkadapu, R., Ilton, E. S., Barkay, T., & Yee, N. (2009) · Environmental Science & Technology · doi:10.1021/es9003608 · Cited by 163 · cited 1×
“12 Besides, magnetite NPs with small sizes have been synthesized and used for removal of heavy metal ions such as Tc(VII) and Cr(VI), 13 As(III), 6 Hg(II), 14 and As(V) 15 from aqueous solutions.”
Heavy metal ions removal from aqueous media by modified magnetic mesoporous silica MCM-48
Anbia, M., Kargosha, K., & Khoshbooei, S. (2014) · Process Safety and Environmental Protection · doi:10.1016/j.cherd.2014.07.018 · Cited by 154 · cited 1×
“7,32 Moreover, at 25 ° C, the solubility product constants of Pb(OH) 2 , Cd(OH) 2 , Cu(OH) 2 , and Ni(OH) 2 are 1.43 × 10 − 20 , 7.20 × 10 − 15 , 2.00 × 10 − 15 , and 5.48 × 10 − 16 , respectively.”
InfluentialCriscenti, L. (1999) · American Journal of Science · doi:10.2475/ajs.299.10.828 · Cited by 145
Removal of Pb(II), Cd(II) and Co(II) from aqueous solution using Garcinia mangostana L. fruit shell
Zein, R., Suhaili, R., Earnestly, F., Indrawati, I., & Munaf, E. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.04.076 · Cited by 144
Wang, Y., Morin, G., Ona-Nguéma, G., Juillot, F., Calas, G., & Brown, G. E. (2011) · Environmental Science & Technology · doi:10.1021/es200299f · Cited by 113
Optimizing Cr(VI) and Tc(VII) Remediation through Nanoscale Biomineral Engineering
Cutting, R. S., Coker, V. S., Telling, N. D., Kimber, R. L., Pearce, C. I., Ellis, B. L., Lawson, R. S., van der Laan, G., Pattrick, R. A. D., Vaughan, D. J., et al. (2010) · Environmental Science & Technology · doi:10.1021/es902119u · Cited by 106
Activated carbon from leather shaving wastes and its application in removal of toxic materials
Kantarli, I. C., & Yanık, J. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.03.012 · Cited by 99
Arsenic removal from aqueous solutions with Fe-hydrotalcite supported magnetite nanoparticle
Türk, T., & Alp, İ. (2013) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2013.06.002 · Cited by 91
Uluözlü, Ö. D., Tüzen, M., Mendil, D., & Soylak, M. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.11.144 · Cited by 71
Faghihian, H., Nourmoradi, H., & Shokouhi, M. (2013) · Desalination and Water Treatment · doi:10.1080/19443994.2013.785367 · Cited by 64
Evaluation of Pb (II) biosorption utilizing sugarcane bagasse colonized by Basidiomycetes
Palin, D., Rufato, K. B., Linde, G. A., Colauto, N. B., Caetano, J., Alberton, O., Jesus, D., & Dragunski, D. C. (2016) · Environmental Monitoring and Assessment · doi:10.1007/s10661-016-5257-8 · Cited by 35 · cited 1×
“31 As the adsorption mechanism is a surface process, the surface of the adsorbent is of great importance for the extent of adsorption and is a key quality parameter.”
Cited by
Removal of heavy metals from wastewater using agricultural byproducts
Alalwan, H. A., Kadhom, M. A., & Alminshid, A. H. (2020) · Journal of Water Supply: Research and Technology-Aqua · doi:10.2166/aqua.2020.133 · Cited by 228
Bayuo, J., Rwiza, M. J., Choi, J. W., Mtei, K. M., Hosseini-Bandegharaei, A., & Sillanpää, M. (2024) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2024.103196 · Cited by 214
Ighalo, J. O., Yap, P.-S., Iwuozor, K. O., Aniagor, C. O., Liu, T., Dulta, K., Iwuchukwu, F. U., & Rangabhashiyam, S. (2022) · Environmental Research · doi:10.1016/j.envres.2022.113123 · Cited by 164
Metadata
- Authors
- Fato, T. P., Li, D.-W., Zhao, L.-J., Qiu, K., & Long, Y.-T.
- Venue
- ACS Omega
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-04-24
- Volume
- 4
- Issue
- 4
- Pages
- 7543-7549
- ISSN
- 2470-1343 (ISSN-L)
- OpenAlex
- W2941619664
- Cited by
- 186
- References
- 32
- FWCI
- 6.25
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.