Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 380

The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.

Infrared-Transparent Visible-Opaque Fabrics for Wearable Personal Thermal Management

Open access
Tong, Jonathan K., Huang, Xiaopeng, Boriskina, Svetlana V., Loomis, James, Xu, Yanfei, Chen, Gang·2015·ACS Photonics

Abstract

Personal cooling technologies locally control the temperature of an individual rather than a large space, thus, providing personal thermal comfort while supplementing cooling loads in thermally regulated environments. This can lead to significant energy and cost savings. In this study, a new approach to personal cooling was developed using an infrared-transparent visible-opaque fabric (ITVOF) that provides passive cooling via the transmission of thermal radiation emitted by the human body directly to the environment. Here, we present a conceptual framework to thermally and optically design an ITVOF. Using a heat transfer model, the fabric was found to require a minimum infrared (IR) transmittance of 0.644 and a maximum IR reflectance of 0.2 to ensure thermal comfort at ambient temperatures as high as 26.1 °C (79 °F). To meet these requirements, an ITVOF design was developed using synthetic polymer fibers with an intrinsically low IR absorptance. These fibers were then structured to minimize IR reflection via weak Rayleigh scattering while maintaining visible opaqueness via strong Mie scattering. For a fabric composed of parallel-aligned polyethylene fibers, numerical finite element simulations predict 1 μm diameter fibers bundled into 30 μm yarns can achieve a total hemispherical IR transmittance of 0.972, which is nearly perfectly transparent to mid- and far-IR radiation. The visible wavelength properties of the ITVOF are comparable to conventional textiles ensuring opaqueness to the human eye. By providing personal cooling in a form amenable to everyday use, ITVOF-based clothing offers a simple, low-cost solution to reduce energy consumption in HVAC systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsphotonics.5b00140

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 35 references

Cited by

See all 380

Metadata

Authors
Tong, J. K., Huang, X., Boriskina, S. V., Loomis, J., Xu, Y., & Chen, G.
Venue
ACS Photonics
Published
2015-06-09
Volume
2
Issue
6
Pages
769-778
ISSN
2330-4022 (ISSN-L)
OpenAlex
W3125316506
Cited by
380
References
35
FWCI
22.01
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Infrared-Transparent Visible-Opaque Fabrics for Wearable Personal Thermal Management. https://app.cochat.ai/papers/10.1021/acsphotonics.5b00140
The paper
Tong, J. K., Huang, X., Boriskina, S. V., Loomis, J., Xu, Y., & Chen, G. (2015). Infrared-Transparent Visible-Opaque Fabrics for Wearable Personal Thermal Management. ACS Photonics. https://doi.org/10.1021/acsphotonics.5b00140

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.