CoChat

Sulfur-Doped Titanium Carbide MXenes for Room-Temperature Gas Sensing

Shuvo, Shoumya Nandy, Ulloa Gomez, Ana Maria, Mishra, Avanish, Chen, Winston Yenyu, Dongare, Avinash M., Stanciu, Lia A. · 2020 · ACS Sensors
Cited by 163

The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.

Abstract

Two-dimensional titanium carbide MXenes, Ti 3 C 2 T x, possess high surface area coupled with metallic conductivity and potential for functionalization. These properties make them especially attractive for the highly sensitive room-temperature electrochemical detection of gas analytes. However, these extraordinary materials have not been thoroughly investigated for the detection of volatile organic compounds (VOCs), many of which hold high relevance for disease diagnostics and environmental protection. Furthermore, the insufficient interlayer spacing between MXene nanoflakes could limit their applicability and the use of heteroatoms as dopants could help overcome this challenge. Here, we report that S-doping of Ti 3 C 2 T x MXene leads to a greater gas-sensing performance to VOCs compared to their undoped counterparts, with unique selectivity to toluene. After S-doped and pristine materials were synthesized, characterized, and used as electrode materials, the as-fabricated sensors were subjected to room-temperature dynamic impedimetric testing in the presence of VOCs with different functional groups (ethanol, hexane, toluene, and hexyl-acetate). Unique selectivity to toluene was obtained by both undoped and doped Ti 3 C 2 T x MXenes, but an enhancement of response in the range of ∼214% at 1 ppm to ∼312% at 50 ppm (3–4 folds increase) was obtained for the sulfur-doped sensing material. A clear notable response to 500 ppb toluene was also obtained with sulfur-doped Ti 3 C 2 T x MXene sensors along with excellent long-term stability. Our experimental measurements and density functional theory analysis offer insight into the mechanisms through which S-doping influences VOC analyte sensing capabilities of Ti 3 C 2 T x MXenes, thus opening up future investigations on the development of high-performance room-temperature gas sensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acssensors.0c01287

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 45 references

Cited by

See all 163

Metadata

Authors
Shuvo, S. N., Ulloa Gomez, A. M., Mishra, A., Chen, W. Y., Dongare, A. M., & Stanciu, L. A.
Venue
ACS Sensors
Published
2020-08-13
Volume
5
Issue
9
Pages
2915-2924
ISSN
2379-3694 (ISSN-L)
OpenAlex
W3049550435
Cited by
163
References
45
FWCI
6.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sulfur-Doped Titanium Carbide MXenes for Room-Temperature Gas Sensing. https://app.cochat.ai/papers/10.1021/acssensors.0c01287
The paper
Shuvo, S. N., Ulloa Gomez, A. M., Mishra, A., Chen, W. Y., Dongare, A. M., & Stanciu, L. A. (2020). Sulfur-Doped Titanium Carbide MXenes for Room-Temperature Gas Sensing. ACS Sensors. https://doi.org/10.1021/acssensors.0c01287

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.