The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Sensing and Bioimaging of the Gaseous Signaling Molecule Hydrogen Sulfide by Near-Infrared Fluorescent Probes
Abstract
A fluorescent probe for the monitoring of H 2 S levels in living cells and organisms is highly desirable. In this regard, near-infrared (NIR) fluorescent probes have emerged as a promising tool. NIR-I and NIR-II probes have many significant advantages; for instance, NIR light penetrates deeper into tissue than light at visible wavelengths, and it causes less photodamage during biosample analysis and less autofluorescence, enabling higher signal-to-background ratios. Therefore, it is expected that fluorescent probes having emission in the NIR region are more suitable for in vivo imaging. Consequently, a considerable increase in reports of new H 2 S-responsive NIR fluorescent probes appeared in the literature. This review highlights the advances made in developing new NIR fluorescent probes aimed at the sensitive and selective detection of H 2 S in biological samples. Their applications in real-time monitoring of H 2 S in cells and in vivo for bioimaging of living cells/animals are emphasized. The selection of suitable dyes for designing NIR fluorescent probes, along with the principles and mechanisms involved for the sensing of H 2 S in the NIR region, are described. The discussions are focused on small-molecule and nanomaterials-based NIR probes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
H 2 S as a Physiologic Vasorelaxant: Hypertension in Mice with Deletion of Cystathionine γ-Lyase
Yang, G., Wu, L., Jiang, B., Yang, W., Qi, J., Cao, K., Meng, Q., Mustafa, A. K., Mu, W., Zhang, S., et al. (2008) · Science · doi:10.1126/science.1162667 · Cited by 2,310
Cited by
Recent progress in the development of fluorescent probes for imaging pathological oxidative stress
Geng, Y., Wang, Z., Zhou, J., Zhu, M., Liu, J., & James, T. D. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00172a · Cited by 351
Recent progress in fluorescent probes for bacteria
Huang, Y., Chen, W., Chung, J., Yin, J., & Yoon, J. (2021) · Chemical Society Reviews · doi:10.1039/d0cs01340d · Cited by 299
Near infrared fluorescent probes for detecting and imaging active small molecules
Ding, C., & Ren, T. (2023) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2023.215080 · Cited by 247
Metadata
- Authors
- Jose, D. A., Sakla, R., Sharma, N., Gadiyaram, S., Kaushik, R., & Ghosh, A.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-11-09
- Volume
- 5
- Issue
- 11
- Pages
- 3365-3391
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W3103323092
- Cited by
- 176
- References
- 1
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensing and Bioimaging of the Gaseous Signaling Molecule Hydrogen Sulfide by Near-Infrared Fluorescent Probes. https://app.cochat.ai/papers/10.1021/acssensors.0c02005
- The paper
- Jose, D. A., Sakla, R., Sharma, N., Gadiyaram, S., Kaushik, R., & Ghosh, A. (2020). Sensing and Bioimaging of the Gaseous Signaling Molecule Hydrogen Sulfide by Near-Infrared Fluorescent Probes. ACS Sensors. https://doi.org/10.1021/acssensors.0c02005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.