The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
CRISPR-Cas12a-Powered Dual-Mode Biosensor for Ultrasensitive and Cross-validating Detection of Pathogenic Bacteria
Abstract
Pathogenic bacteria infection severely threatens human health and causes substantial medical and financial concern. Rapid, sensitive, specific, and reliable detection of pathogenic bacteria is crucial. In the current study, a CRISPR-Cas12a-powered dual-mode biosensor was developed for ultrasensitive and cross-validating detection of pathogenic bacteria. Simply, the amplicons of Salmonella (used as a model)-specific invA sequence triggered CRISPR-Cas12a-based indiscriminate degradation of single-stranded DNAs that were supposed to link two gold nanoparticle (AuNP) probe pairs, inducing an aggregation-to-dispersion change. This generated observable color changes that became even more apparent after centrifugation. The color changes can be discerned by naked eyes and recorded using a portable colorimeter. Meanwhile, the photothermal effect of CRISPR-Cas12-powered AuNPs was explored for the first time through 808 nm near-infrared irradiation such that quantitative measurement can be carried out by recording temperatures using a thermal camera. For both modes, a limit of detection of 1 CFU/mL and a dynamic range of detection from 10 0 to 10 8 CFU/mL were obtained, which were comparable with or better than previously reported methods. Our proposed biosensor demonstrated satisfactory selectivity for Salmonella against other interfering cells. Furthermore, this biosensor proved to be capable of Salmonella detection in food samples. Regarding the real applications, the result from each mode can be used for cross-validation. Only the case having doubly confirmed positive or negative results can be assured, which rendered a more dependable biosensing conclusion. This technology not only expands the reach of the CRISPR-Cas system in biosensing but also provides a general method for bacteria sensing with desirable sensitivity, specificity, and cross-validating capacity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRISPR-Cas12a target binding unleashes indiscriminate single-stranded DNase activity
Chen, J. S., Ma, E., Harrington, L. B., Da Costa, M., Tian, X., Palefsky, J. M., & Doudna, J. A. (2018) · Science · doi:10.1126/science.aar6245 · Cited by 4,507
Cited by
Zhuang, J., Zhao, Z., Lian, K., Yin, L., Wang, J., Man, S., Liu, G., & Ma, L. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114167 · Cited by 295
Self-citation
Metadata
- Authors
- Ma, L., Peng, L., Yin, L., Liu, G., & Man, S.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-07-19
- Volume
- 6
- Issue
- 8
- Pages
- 2920-2927
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W3183397623
- Cited by
- 181
- References
- 1
- FWCI
- 9.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CRISPR-Cas12a-Powered Dual-Mode Biosensor for Ultrasensitive and Cross-validating Detection of Pathogenic Bacteria. https://app.cochat.ai/papers/10.1021/acssensors.1c00686
- The paper
- Ma, L., Peng, L., Yin, L., Liu, G., & Man, S. (2021). CRISPR-Cas12a-Powered Dual-Mode Biosensor for Ultrasensitive and Cross-validating Detection of Pathogenic Bacteria. ACS Sensors. https://doi.org/10.1021/acssensors.1c00686
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.