CoChat

Plasmonic Coupling of Au Nanoclusters on a Flexible MXene/Graphene Oxide Fiber for Ultrasensitive SERS Sensing

Open access
Liu, Xin, Dang, Alei, Li, Tiehu, Sun, Yiting, Lee, Tung-Chun, Deng, Weibin, Wu, Shaoheng, Zada, Amir, Zhao, Tingkai, Li, Hao · 2023 · ACS Sensors
Cited by 192

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

High sensitivity, good signal repeatability, and facile fabrication of flexible surface enhanced Raman scattering (SERS) substrates are common pursuits of researchers for the detection of probe molecules in a complex environment. However, fragile adhesion between the noble-metal nanoparticles and substrate material, low selectivity, and complex fabrication process on a large scale limit SERS technology for wide-ranging applications. Herein, we propose a scalable and cost-effective strategy to a fabricate sensitive and mechanically stable flexible Ti 3 C 2 T x MXene@graphene oxide/Au nanoclusters (MG/AuNCs) fiber SERS substrate from wet spinning and subsequent in situ reduction processes. The use of MG fiber provides good flexibility (114 MPa) and charge transfer enhancement (chemical mechanism, CM) for a SERS sensor and allows further in situ growth of AuNCs on its surface to build highly sensitive hot spots (electromagnetic mechanism, EM), promoting the durability and SERS performance of the substrate in complex environments. Therefore, the formed flexible MG/AuNCs-1 fiber exhibits a low detection limit of 1 × 10 –11 M with a 2.01 × 10 9 enhancement factor (EF exp ), signal repeatability (RSD = 9.80%), and time retention (remains 75% after 90 days of storage) for R6G molecules. Furthermore, the l -cysteine-modified MG/AuNCs-1 fiber realized the trace and selective detection of trinitrotoluene (TNT) molecules (0.1 μM) via Meisenheimer complex formation, even by sampling the TNT molecules at a fingerprint or sample bag. These findings fill the gap in the large-scale fabrication of high-performance 2D materials/precious-metal particle composite SERS substrates, with the expectation of pushing flexible SERS sensors toward wider applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acssensors.2c02808

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Liu, X., Dang, A., Li, T., Sun, Y., Lee, T.-C., Deng, W., Wu, S., Zada, A., Zhao, T., & Li, H.
Venue
ACS Sensors
Published
2023-03-03
Volume
8
Issue
3
Pages
1287-1298
ISSN
2379-3694 (ISSN-L)
OpenAlex
W4323037641
Cited by
192
References
2
FWCI
11.37
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.