The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Rapid-Response, Widely Stretchable Sensor of Aligned MWCNT/Elastomer Composites for Human Motion Detection
Abstract
We studied the use of carbon-nanotube- (CNT)-based strain sensors as components of a textile-based, wearable sensing system for real-time motion detection. In the stretchable sensor, millimeter-long multiwalled CNTs (MWCNTs) are unidirectionally aligned and sandwiched between elastomer layers. We synthesized urethane resin to make the elastomer, which exhibits low elasticity and an affinity for human skin. The aligned CNT layer was formed by stacking CNT webs drawn from a spinnable CNT forest. The stretchable sensor can be stretched up to 200% and exhibits a short sensing delay of less than 15 ms. The gauge factor exceeds 10, which indicates high sensitivity. Moreover, the device is thin and as soft as human skin. The demonstrated flexibility and conformable nature make this material ideally suited for wearable sensors, specifically for a textile-based, wearable, real-time, human body motion-sensing application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296
Flexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
A Highly Elastic, Capacitive Strain Gauge Based on Percolating Nanotube Networks
Cohen, D. J., Mitra, D., Peterson, K., & Maharbiz, M. M. (2012) · Nano Letters · doi:10.1021/nl204052z · Cited by 501
Hu, W., Niu, X., Zhao, R., & Pei, Q. (2013) · Applied Physics Letters · doi:10.1063/1.4794143 · Cited by 332
Cited by
Wen, F., Zhang, Z., He, T., & Lee, C. (2021) · Nature Communications · doi:10.1038/s41467-021-25637-w · Cited by 494
Wen, F., Sun, Z., He, T., Shi, Q., Zhu, M., Zhang, Z., Li, L., Zhang, T., & Lee, C. (2020) · Advanced Science · doi:10.1002/advs.202000261 · Cited by 478
Li, Y., Zhou, B., Zheng, G., Liu, X., Li, T., Yan, C., Cheng, C., Dai, K., Liu, C., Shen, C., et al. (2018) · Journal of Materials Chemistry C · doi:10.1039/c7tc04959e · Cited by 459
Applications of nanotechnology in smart textile industry: A critical review
Shah, M. A., Pirzada, B. M., Price, G., Shibiru, A. L., & Qurashi, A. (2022) · Journal of Advanced Research · doi:10.1016/j.jare.2022.01.008 · Cited by 412
Shintake, J., Piskarev, Y., Jeong, S. H., & Floreano, D. (2018) · Advanced Materials Technologies · doi:10.1002/admt.201700284 · Cited by 332
Metadata
- Authors
- Suzuki, K., Yataka, K., Okumiya, Y., Sakakibara, S., Sako, K., Mimura, H., & Inoue, Y.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-05-31
- Volume
- 1
- Issue
- 6
- Pages
- 817-825
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W2403156747
- Cited by
- 205
- References
- 5
- FWCI
- 9.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid-Response, Widely Stretchable Sensor of Aligned MWCNT/Elastomer Composites for Human Motion Detection. https://app.cochat.ai/papers/10.1021/acssensors.6b00145
- The paper
- Suzuki, K., Yataka, K., Okumiya, Y., Sakakibara, S., Sako, K., Mimura, H., & Inoue, Y. (2016). Rapid-Response, Widely Stretchable Sensor of Aligned MWCNT/Elastomer Composites for Human Motion Detection. ACS Sensors. https://doi.org/10.1021/acssensors.6b00145
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.