The DOI matches its Crossref record.
Development of a Lower Toxic Approach Based on Green Synthesis of Water-Compatible Molecularly Imprinted Nanoparticles for the Extraction of Hydrochlorothiazide from Human Urine
Abstract
In the present paper, one-pot green syntheses of novel hydrophilic and superparamagnetic molecularly imprinted polymers (MMIPs) for the cleanup and extraction of hydrochlorothiazide (HCT) in human urine are described. The MMIPs were prepared via a sol–gel process using Fe 3 O 4 magnetite as a magnetic component, HCT as a template, tetraethyl orthosilicate (TEOS) as the cross-linker, and 3-aminopropyl trimethoxysilane (APTMS) as the functionalized monomer, which could simplify the imprinting process. During the synthesis process, a surfactant was especially used to graft the silica-imprinted nanoparticles. The key step of this research is mild working temperature without consuming any organic solvent during the synthesis of MMIPs in addition to its ability for efficient and highly selective enrichment of HCT in complicated human urine. The morphology, structure, and magnetic properties of the MMIPs were characterized using scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR), and vibrating sample magnetometry (VSM). The prepared MMIPs were found to be superparamagnetic, which makes them easy to be quickly separated from the sample solution and thus decreases the extraction time. After the dispersive solid phase extraction (d-SPE) by the prepared MMIPs, high performance liquid chromatography (HPLC) was used to determine the target analyte, HCT. Several factors affecting the extraction efficiency, including the pH of the sample solution, the amount of adsorbent, sonication time, eluent, and washing solvent volumes, were evaluated, and the optimum conditions were obtained using the experimental design methodology. Under the optimized conditions, the developed MMIPs-d-SPE linearly responded over 2.5–1000 μg L –1 while a detection limit of 0.75 μg L –1 was obtained. The high selectivity of this method makes it suitable for successful monitoring of analyte in a real sample such as urine with satisfactory recoveries of 90.7–110.0% with the precision of 0.8–6.6%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Arabi, M., Ostovan, A., Bagheri, A. R., Guo, X., Li, J., Ma, J., & Chen, L. (2020) · Talanta · doi:10.1016/j.talanta.2020.120933 · Cited by 222
Self-citationZahiri, E., Khandaghi, J., Farajzadeh, M. A., & Afshar Mogaddam, M. R. (2020) · Journal of Chromatography A · doi:10.1016/j.chroma.2020.461390 · Cited by 86
Afshar Mogaddam, M. R., Farajzadeh, M. A., Azadmard Damirchi, S., & Nemati, M. (2020) · Journal of Chromatography A · doi:10.1016/j.chroma.2020.461523 · Cited by 65
Farajzadeh, M. A., Abbaspour, M., & Kazemian, R. (2019) · Journal of Chromatography A · doi:10.1016/j.chroma.2019.06.051 · Cited by 56
Magnetic metal organic framework for pre-concentration of ampicillin from cow milk samples
Bagheri, A. R., & Ghaedi, M. (2020) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2020.02.006 · Cited by 46
Self-citation
Metadata
- Authors
- Arabi, M., Ghaedi, M., & Ostovan, A.
- Venue
- ACS Sustainable Chemistry & Engineering
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-04-14
- Volume
- 5
- Issue
- 5
- Pages
- 3775-3785
- ISSN
- 2168-0485 (ISSN-L)
- OpenAlex
- W2605872514
- Cited by
- 237
- References
- 0
- FWCI
- 31.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a Lower Toxic Approach Based on Green Synthesis of Water-Compatible Molecularly Imprinted Nanoparticles for the Extraction of Hydrochlorothiazide from Human Urine. https://app.cochat.ai/papers/10.1021/acssuschemeng.6b02615
- The paper
- Arabi, M., Ghaedi, M., & Ostovan, A. (2017). Development of a Lower Toxic Approach Based on Green Synthesis of Water-Compatible Molecularly Imprinted Nanoparticles for the Extraction of Hydrochlorothiazide from Human Urine. ACS Sustainable Chemistry & Engineering. https://doi.org/10.1021/acssuschemeng.6b02615
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.