The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Carbon Aerogel Composites Prepared by Ambient Drying and Using Oxidized Polyacrylonitrile Fibers as Reinforcements
Abstract
Carbon fiber-reinforced carbon aerogel composites (C/CAs) for thermal insulators were prepared by copyrolysis of resorcinol-formaldehyde (RF) aerogels reinforced by oxidized polyacrylonitrile (PAN) fiber felts. The RF aerogel composites were obtained by impregnating PAN fiber felts with RF sols, then aging, ethanol exchanging, and drying at ambient pressure. Upon carbonization, the PAN fibers shrink with the RF aerogels, thus reducing the difference of shrinkage rates between the fiber reinforcements and the aerogel matrices, and resulting in C/CAs without any obvious cracks. The three point bend strength of the C/CAs is 7.1 ± 1.7 MPa, and the thermal conductivity is 0.328 W m(-1) K(-1) at 300 °C in air. These composites can be used as high-temperature thermal insulators (in inert atmospheres or vacuum) or supports for phase change materials in thermal protection system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chemistry of Aerogels and Their Applications
Pierre, A. C., & Pajonk, G. M. (2002) · Chemical Reviews · doi:10.1021/cr0101306 · Cited by 2,239
Synthesis of Graphene Aerogel with High Electrical Conductivity
Worsley, M. A., Pauzauskie, P. J., Olson, T. Y., Biener, J., Satcher, J. H., & Baumann, T. F. (2010) · Journal of the American Chemical Society · doi:10.1021/ja1072299 · Cited by 1,216
Tailoring Mechanical Properties of Aerogels for Aerospace Applications
Randall, J. P., Meador, M. A. B., & Jana, S. C. (2011) · ACS Applied Materials & Interfaces · doi:10.1021/am200007n · Cited by 579
Ultralight Multiwalled Carbon Nanotube Aerogel
Zou, J., Liu, J., Karakoti, A. S., Kumar, A., Joung, D., Li, Q., Khondaker, S. I., Seal, S., & Zhai, L. (2010) · ACS Nano · doi:10.1021/nn102246a · Cited by 509
Thermal conductivity of low density carbon aerogels
Feng, J., Feng, J., & Zhang, C. (2012) · Journal of Porous Materials · doi:10.1007/s10934-011-9504-7 · Cited by 81
Self-citation
Cited by
Recent advances in preparations and applications of carbon aerogels: A review
Lee, J.-H., & Park, S.-J. (2020) · Carbon · doi:10.1016/j.carbon.2020.02.073 · Cited by 471
Li, F., Xie, L., Sun, G., Kong, Q., Su, F., Cao, Y., Wei, J., Ahmad, A., Guo, X., & Chen, C.-M. (2019) · Microporous and Mesoporous Materials · doi:10.1016/j.micromeso.2018.12.007 · Cited by 126
Metadata
- Authors
- Feng, J., Zhang, C., Feng, J., Jiang, Y., & Zhao, N.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-11-14
- Volume
- 3
- Issue
- 12
- Pages
- 4796-4803
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2001577237
- Cited by
- 163
- References
- 5
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Carbon Aerogel Composites Prepared by Ambient Drying and Using Oxidized Polyacrylonitrile Fibers as Reinforcements. https://app.cochat.ai/papers/10.1021/am201287a
- The paper
- Feng, J., Zhang, C., Feng, J., Jiang, Y., & Zhao, N. (2011). Carbon Aerogel Composites Prepared by Ambient Drying and Using Oxidized Polyacrylonitrile Fibers as Reinforcements. ACS Applied Materials & Interfaces. https://doi.org/10.1021/am201287a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.