Preparation and Fuel Cell Performance of Catalyst Layers Using Sulfonated Polyimide Ionomers
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Sulfonated polyimide (SPI-8) ionomers were used as binders in the catalyst layers, and their fuel cell performance was evaluated. SPI-8 ionomers functioned well in the anode with only minor overpotential even at low humidity (50% relative humidity (RH)). In contrast, the cathode performance was significantly dependent on the content and molecular weight of the ionomers and humidity of the supplied gases. Higher molecular weight of the ionomer caused larger potential drop at high current density at 80 and 100% RH since oxygen supply and/or water discharge became insufficient due to higher water uptake (swelling) of the ionomer. Similar results were obtained at higher ionomer content, because of the increase of thickness in the catalyst layer. The mass transport was improved with decreasing humidity, however, proton conductivity became lower. While the maximum values of j(@0.70 V) for all membrane electrode assemblies (MEAs) were ca. 0.35 A/cm(2), each electrode could have the different appropriate operating conditions. The results suggest that the parameters such as oxygen supply, proton conductivity, and water uptake and discharge need to be carefully optimized in the catalyst layers for achieving reasonable cathode performance with hydrocarbon ionomers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Uchida, M., Fukuoka, Y., Sugawara, Y., Eda, N., & Ohta, A. (1996) · Journal of The Electrochemical Society · doi:10.1149/1.1836988 · Cited by 309
Self-citation
Cited by
The Controllable Design of Catalyst Inks to Enhance PEMFC Performance: A Review
Guo, Y., Pan, F., Chen, W., Ding, Z., Yang, D., Li, B., Ming, P., & Zhang, C. (2021) · Electrochemical Energy Reviews · doi:10.1007/s41918-020-00083-2 · Cited by 175
“Due to the low temperature resistance, poor environmental compatibility and high cost of PFSA ionomers, increasing research has been conducted in the development of non-fluorinated hydrocarbon ionomers such as sulfonated poly(arylene ether sulfone) [116, 117], sulfonated poly (ether ether ketone) [118, 119] and sulfon…”
BackgroundPark, Y.-C., Kakinuma, K., Uchida, H., Watanabe, M., & Uchida, M. (2015) · Journal of Power Sources · doi:10.1016/j.jpowsour.2014.10.149 · Cited by 123
Self-citationUchida, M., Park, Y.-C., Kakinuma, K., Yano, H., Tryk, D. A., Kamino, T., Uchida, H., & Watanabe, M. (2013) · Physical Chemistry Chemical Physics · doi:10.1039/c3cp51801a · Cited by 122
Self-citationNano-scale control of the ionomer distribution by molecular masking of the Pt surface in PEMFCs
Doo, G., Yuk, S., Lee, J. H., Choi, S., Lee, D.-H., Lee, D. W., Hyun, J., Kwon, S. H., Lee, S. G., & Kim, H.-T. (2020) · Journal of Materials Chemistry A · doi:10.1039/c9ta14002f · Cited by 99
Song, C.-H., & Park, J.-S. (2019) · Energies · doi:10.3390/en12030549 · Cited by 54
Metadata
- Authors
- Omata, T., Tanaka, M., Miyatake, K., Uchida, M., Uchida, H., & Watanabe, M.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-01-17
- Volume
- 4
- Issue
- 2
- Pages
- 730-737
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2318655729
- Cited by
- 39
- References
- 1
- FWCI
- 1.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.