Effect of Humidity on Nanoparticle-Based Chemiresistors: A Comparison between Synthetic and Real-World Samples
The DOI matches its Crossref record.
Abstract
Chemiresistors based on metal monolayer-capped nanoparticles (MCNPs) are promising candidates for fast, inexpensive, and portable tracing of (bio)chemical species in the gas phase. However, the sensitivity of such sensors to humidity is problematic, limiting their reliable and reproducible application in real-world environmental conditions. In this work, we employed a compensation method to explore the effect of humidity on a single MCNP chemiresistor as well as on an array of MCNP sensors used to analyze either synthetic or real-world samples. We show that an array of MCNP chemiresistors is able to precisely detect and estimate subtle concentrations of (mixtures of) volatile organic compounds (VOCs) under variable backgrounds of 2-83% relative humidity (RH) only after humidity compensation. Humidity effects were also tested in two clinical trials aimed at detecting prostate cancer and breast cancer through exhaled breath analysis. Analysis of the results showed improved cancer detection capabilities as a result of RH compensation, though less substantial than the impact of RH compensation on synthetic samples. This outcome is attributed to one - or a combination - of the following effects: (i) the RH variance was smaller in the breath samples than that in the synthetic samples; (ii) the VOC composition in the breath samples is less controlled than the synthetic samples; and (iii) the responses to small polar VOCs and water are not necessarily additive in breath samples. Ultimately, the results presented here could assist the development of a cost-effective, low-power method for widespread detection of VOCs in real-world applications, such as breath analysis, as well as for environmental, security, and food applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mirzaei, A., Leonardi, S. G., & Neri, G. (2016) · Ceramics International · doi:10.1016/j.ceramint.2016.06.145 · Cited by 1,174
Graphene–metal oxide nanohybrids for toxic gas sensor: A review
Gupta Chatterjee, S., Chatterjee, S., Ray, A. K., & Chakraborty, A. K. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.07.070 · Cited by 737
Assessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Self-citationSensors for Breath Testing: From Nanomaterials to Comprehensive Disease Detection
Konvalina, G., & Haick, H. (2014) · Accounts of Chemical Research · doi:10.1021/ar400070m · Cited by 561
Self-citationFlexible Sensors Based on Nanoparticles
Segev-Bar, M., & Haick, H. (2013) · ACS Nano · doi:10.1021/nn402728g · Cited by 511
Self-citation
Metadata
- Authors
- Konvalina, G., & Haick, H.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-12-15
- Volume
- 4
- Issue
- 1
- Pages
- 317-325
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2319444954
- Cited by
- 149
- References
- 0
- FWCI
- 10.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Humidity on Nanoparticle-Based Chemiresistors: A Comparison between Synthetic and Real-World Samples. https://app.cochat.ai/papers/10.1021/am2013695
- The paper
- Konvalina, G., & Haick, H. (2012). Effect of Humidity on Nanoparticle-Based Chemiresistors: A Comparison between Synthetic and Real-World Samples. ACS Applied Materials & Interfaces. https://doi.org/10.1021/am2013695
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.