The DOI matches its Crossref record.
Mechanical, In vitro Antimicrobial, and Biological Properties of Plasma-Sprayed Silver-Doped Hydroxyapatite Coating
Open accessAbstract
Implant-related infection is one of the key concerns in total joint hip arthroplasties. To reduce bacterial adhesion, we used silver (Ag)/silver oxide (Ag(2)O) doping in plasma sprayed hydroxyapatite (HA) coating on titanium substrate. HA powder was doped with 2.0, 4.0, and 6.0 wt % Ag, heat-treated at 800 °C and used for plasma spray coating using a 30 kW plasma spray system, equipped with supersonic nozzle. Application of supersonic plasma nozzle significantly reduced phase decomposition and amorphous phase formation in the HA coatings as evident by X-ray diffraction (XRD) study and Fourier transformed infrared spectroscopic (FTIR) analysis. Adhesive bond strength of more than 15 MPa ensured the mechanical integrity of the coatings. Resistance against bacterial adhesion of the coatings was determined by challenging them against Pseudomonas aeruginosa (PAO1). Live/dead staining of the adherent bacteria on the coating surfaces indicated a significant reduction in bacterial adhesion due to the presence of Ag. In vitro cell-material interactions and alkaline phosphatase (ALP) protein expressions were evaluated by culturing human fetal osteoblast cells (hFOB). Our results suggest that the plasma-sprayed HA coatings doped with an optimum amount of Ag can have excellent antimicrobial property without altering mechanical property of the Ag-doped HA coatings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Antibacterial Coatings: Challenges, Perspectives, and Opportunities
Cloutier, M., Mantovani, D., & Rosei, F. (2015) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.09.002 · Cited by 813
Nanobio Silver: Its Interactions with Peptides and Bacteria, and Its Uses in Medicine
Eckhardt, S., Brunetto, P. S., Gagnon, J., Priebe, M., Giese, B., & Fromm, K. M. (2013) · Chemical Reviews · doi:10.1021/cr300288v · Cited by 794
Substituted hydroxyapatite coatings of bone implants
Arcos, D., & Vallet-Regí, M. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02710f · Cited by 415
Hydroxyapatite Based Materials for Bone Tissue Engineering: A Brief and Comprehensive Introduction
Shi, H., Zhou, Z., Li, W., Fan, Y., Li, Z., & Wei, J. (2021) · Crystals · doi:10.3390/cryst11020149 · Cited by 310
Surface modification of biomaterials and biomedical devices using additive manufacturing
Bose, S., Robertson, S. F., & Bandyopadhyay, A. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.11.003 · Cited by 305
Self-citationSubstituted Hydroxyapatites with Antibacterial Properties
Kolmas, J., Groszyk, E., & Kwiatkowska-Różycka, D. (2014) · BioMed Research International · doi:10.1155/2014/178123 · Cited by 273
Ionic substituted hydroxyapatite for bone regeneration applications: A review
Ressler, A., Žužić, A., Ivanišević, I., Kamboj, N., & Ivanković, H. (2021) · Open Ceramics · doi:10.1016/j.oceram.2021.100122 · Cited by 254
Chen, B., Lin, T., Yang, X., Li, Y., Xie, D., Zheng, W., Cui, H., Deng, W., & Tan, X. (2016) · International Journal of Molecular Medicine · doi:10.3892/ijmm.2016.2757 · Cited by 42
Metadata
- Authors
- Roy, M., Fielding, G. A., Beyenal, H., Bandyopadhyay, A., & Bose, S.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-02-28
- Volume
- 4
- Issue
- 3
- Pages
- 1341-1349
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2064813687
- Cited by
- 199
- References
- 0
- FWCI
- 6.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.