The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Blood Compatibility of Iron-Doped Nanosize Hydroxyapatite and Its Drug Release
Abstract
Nanosize hydroxyapatite (nHAp) doped with varying levels of Fe(3+) (Fe-nHAp of average size 75 nm) was synthesized by hydrothermal and microwave techniques. The samples were characterized for physiochemical properties by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), inductively coupled plasma optical emission spectrometer (ICP-OES), transmission electron microscopy (TEM), vibrating sample magnetometer (VSM), mechanical and dielectric properties. The biological properties like hemocompatibility, antibacterial efficacy, in vitro bioactivity and the cell proliferation of the samples were determined. XRD pattern of the samples were of single phase hydroxyapatite. As the content of Fe(3+) increased, the crystallite size as well as crystallinity decreased along with a morphological change from spherulites to rods. The dielectric constants and Vickers hardness were enhanced on Fe(3+) doping. The VSM studies revealed that the saturation magnetization (M(s)) and retentivity (M(r)) were found to increase for Fe-nHAp. nHAp impregnated with an antibiotic as a new system for drug delivery in the treatment of chronic osteomyelitis was also attempted. The in vitro drug release with an antibiotic amoxicillin and anticancer drug 5-fluorouracil showed sustained release for the lowest concentration of Fe(3+), while with an increase in the content; there was a rapid release of the drug. The hemolytic assay of Fe(3+) doped samples revealed high blood compatibility (<5% hemolysis). The antibacterial activities of the antibiotic impregnated materials were tested against a culture of E. coli, S. epidermidis and S. aureus by agar diffusion test. The in vitro bioactivity test using simulated body fluid (SBF) showed better bone bonding ability by the formation of an apatite layer on the doped samples. The growth of the apatite layer on the samples surface has been confirmed by EDS analysis. The proliferative potential of MG63 cells by MTT assay confirmed the noncytotoxicity of the samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Therapeutic applications of implantable drug delivery systems
Dash, A., & Cudworth, G. (1998) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/s1056-8719(98)00027-6 · Cited by 358
Cited by
Tite, T., Popa, A.-C., Balescu, L. M., Bogdan, I. M., Pasuk, I., Ferreira, J. M. F., & Stan, G. E. (2018) · Materials · doi:10.3390/ma11112081 · Cited by 282
Calcium-based biomaterials for diagnosis, treatment, and theranostics
Qi, C., Lin, J., Fu, L.-H., & Huang, P. (2018) · Chemical Society Reviews · doi:10.1039/c6cs00746e · Cited by 265
Zheng, F., Wang, S., Wen, S., Shen, M., Zhu, M., & Shi, X. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2012.10.071 · Cited by 255
Metadata
- Authors
- Sarath Chandra, V., Baskar, G., Suganthi, R. V., Elayaraja, K., Ahymah Joshy, M. I., Sofi Beaula, W., Mythili, R., Venkatraman, G., & Narayana Kalkura, S.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-03-05
- Volume
- 4
- Issue
- 3
- Pages
- 1200-1210
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2018495461
- Cited by
- 218
- References
- 1
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.