Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 264

The DOI matches its Crossref record.

Surface Science and Electrochemical Analysis of Nickel Foams

Grdeń, Michał, Alsabet, Mohammad, Jerkiewicz, Gregory·2012·ACS Applied Materials & Interfaces

Abstract

Open-pore nickel (Ni) foams are characterized using surface science and electrochemical techniques. A scanning electron microscopy analysis reveals interconnected Ni struts that generate small and large pores of ca. 50 and 500 μm in size, respectively. An X-ray photoelectron spectroscopy (XPS) analysis of the surface-chemical composition of the Ni foams shows that there are oxidized and metallic sections within their surfaces despite being prepared by sintering in an oxidizing atmosphere at a high temperature and being stored in moist air. The ratio of the areas of oxidized and metallic sections is evaluated using XPS data. Chemical etching of the Ni foams results in removal of the native surface oxide/hydroxide without altering the three-dimensional structure; it also increases the roughness (R) of the surfaces of Ni struts giving rise to an increase in the electrochemically active surface area (Aecsa). Thermal treatment of Ni foams in an H2(g) atmosphere at 500 °C reduces the native surface oxide/hydroxide but does not increase R or Aecsa. Electrochemical behavior of the Ni foams is examined in 0.5 M aqueous KOH solution using cyclic-voltammetry (CV) and electrochemical impedance spectroscopy (EIS). As-received, chemically etched, thermally reduced and electro-oxidized Ni foams generate distinct CV profiles; their features are assigned to oxidized and metallic surface states. The observations made on the basis of XPS measurements are corroborated by the results of CV analyses. The application of CV and XPS or EIS allows in situ determination of Aecsa and the specific surface area (As) of the chemically etched and thermally reduced Ni foams. The values of As determined on the basis of joint CV and XPS measurements are 227 ± 74 and 149 ± 48 cm(2) g(-1) for the etched and reduced Ni foams, respectively. The values of As determined on the basis of CV, XPS and EIS measurements are 241 ± 80 and 160 ± 23 cm g(-1) for the etched and reduced Ni foams, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/am300380m

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 264

Metadata

Authors
Grdeń, M., Alsabet, M., & Jerkiewicz, G.
Venue
ACS Applied Materials & Interfaces
Published
2012-05-21
Volume
4
Issue
6
Pages
3012-3021
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2333038648
Cited by
264
References
0
FWCI
4.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Surface Science and Electrochemical Analysis of Nickel Foams. https://app.cochat.ai/papers/10.1021/am300380m
The paper
Grdeń, M., Alsabet, M., & Jerkiewicz, G. (2012). Surface Science and Electrochemical Analysis of Nickel Foams. ACS Applied Materials & Interfaces. https://doi.org/10.1021/am300380m

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.