The DOI matches its Crossref record.
Highly Sensitive SERS Detection of Hg2+ Ions in Aqueous Media Using Gold Nanoparticles/Graphene Heterojunctions
Abstract
Gold nanoparticles (AuNPs)/reduced graphene oxide (rGO) heterojunctions were synthesized directly on SiO2/Si substrates via a seed-assisted growth process. The in situ chemical fabrication strategy has been proven to be quite simple and efficient for generating highly active surface-enhanced Raman scattering (SERS) substrates due to synergistic enhanced protocol from rGO and AuNPs. The SERS substrates with AuNPs/rGO heterojunctions have been utilized for trace analysis of mercury(II) ions via thymine-Hg(2+)-thymine coordination. Thereby, very low limits of detection, i.e., 0.1 nM or 20 ppt for Hg(2+), can be achieved in contrast with some other SERS subsrtates, which suggests that the heterojunctions are appropriate as versatile surface-enhanced substrates applied in chemical sensing or biosensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
SERS-Activated Platforms for Immunoassay: Probes, Encoding Methods, and Applications
Wang, Z., Zong, S., Wu, L., Zhu, D., & Cui, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00027 · Cited by 614
Ha, M., Kim, J.-H., You, M., Li, Q., Fan, C., & Nam, J.-M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00234 · Cited by 466
Yan, F., Zou, Y., Wang, M., Mu, X., Yang, N., & Chen, L. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.11.041 · Cited by 298
Liu, M., Wang, Z., Zong, S., Chen, H., Zhu, D., Wu, L., Hu, G., & Cui, Y. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am5006282 · Cited by 178
Metadata
- Authors
- Ding, X., Kong, L., Wang, J., Fang, F., Li, D., & Liu, J.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-07-26
- Volume
- 5
- Issue
- 15
- Pages
- 7072-7078
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2072909066
- Cited by
- 174
- References
- 0
- FWCI
- 7.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.