The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fast Responding Exhaled-Breath Sensors Using WO3 Hemitubes Functionalized by Graphene-Based Electronic Sensitizers for Diagnosis of Diseases
Abstract
Diagnostic sensing device using exhaled breath of human have critical advantages due to the noninvasive diagnosis and high potential for portable device with simple analysis process. Here, we report ultrafast as well as highly sensitive bumpy WO3 hemitube nanostructure assisted by O2 plasma surface modification with functionalization of graphene-based material for the detection of acetone (CH3COCH3) and hydrogen sulfide (H2S) which are biomarkers for the diagnosis of diabetes and halitosis, respectively. 0.1 wt % graphene oxide (GO)- and 0.1 wt % thin layered graphite (GR)- WO3 hemitube composites showed response times of 11.5 ± 2.5 s and 13.5 ± 3.4 s to 1 ppm acetone as well as 12.5 ± 1.9 s and 10.0 ± 1.6 s to 1 ppm of H2S, respectively. In addition, low limits of detection (LOD) of 100 ppb (Rair/Rgas = 1.7 for acetone and Rair/Rgas = 3.3 for H2S at 300 °C) were achieved. The superior sensing properties were ascribed to the electronic sensitization of graphene based materials by modulating space charged layers at the interfaces between n-type WO3 hemitubes and p-type graphene based materials, as identified by Kelvin Probe Force Microscopy (KPFM). Rapid response and superior sensitivity of the proposed sensing materials following cyclic thermal aging demonstrates good potential for real-time exhaled breath diagnosis of diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanostructured Tungsten Oxide – Properties, Synthesis, and Applications
Zheng, H., Ou, J. Z., Strano, M. S., Kaner, R. B., Mitchell, A., & Kalantar‐zadeh, K. (2011) · Advanced Functional Materials · doi:10.1002/adfm.201002477 · Cited by 1,479
Cited by
Spinel ferrite oxide semiconductor gas sensors
Šutka, A., & Gross, K. A. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.08.027 · Cited by 530
Resistance-based H2S gas sensors using metal oxide nanostructures: A review of recent advances
Mirzaei, A., Kim, S. S., & Kim, H. W. (2018) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2018.06.015 · Cited by 465
Recent progress in applications of graphene oxide for gas sensing: A review
Toda, K., Furue, R., & Hayami, S. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.002 · Cited by 427
Selectivity in Chemiresistive Gas Sensors: Strategies and Challenges
Bulemo, P. M., Kim, D.-H., Shin, H., Cho, H.-J., Koo, W.-T., Choi, S.-J., Park, C., Ahn, J., Güntner, A. T., Penner, R. M., et al. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00592 · Cited by 418
Self-citationGraphene-based hybrids for chemiresistive gas sensors
Meng, F.-L., Guo, Z., & Huang, X.-J. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.02.008 · Cited by 337
Metadata
- Authors
- Choi, S.-J., Fuchs, F., Demadrille, R., Grévin, B., Jang, B.-H., Lee, S.-J., Lee, J.-H., Tuller, H. L., & Kim, I.-D.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-06-03
- Volume
- 6
- Issue
- 12
- Pages
- 9061-9070
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2325693181
- Cited by
- 183
- References
- 1
- FWCI
- 9.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.